The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Amplitude-modulated Continuous Arterial Spin-labeling 3.0-T Perfusion MR Imaging with a Single Coil: Feasibility Study
Abstract
Written informed consent was obtained prior to all human studies after the institutional review board approved the protocol. A continuous arterial spin-labeling technique with an amplitude-modulated control was implemented by using a single coil at 3.0 T. Adiabatic inversion efficiency at 3.0 T, comparable to that at 1.5 T, was achieved by reducing the amplitude of radiofrequency pulses and gradient strengths appropriately. The amplitude-modulated control provided a good match for the magnetization transfer effect of labeling pulses, allowing multisection perfusion magnetic resonance imaging of the whole brain. Comparison of multisection continuous and pulsed arterial spin-labeling methods at 3.0 T showed a 33% improvement in signal-to-noise ratio by using the former approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
Self-citationTechnical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
Self-citation
Cited by
Perfusion functional MRI reveals cerebral blood flow pattern under psychological stress
Wang, J., Rao, H., Wetmore, G. S., Furlan, P. M., Korczykowski, M., Dinges, D. F., & Detre, J. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503082102 · Cited by 513
Self-citationNeural substrates of abstinence-induced cigarette cravings in chronic smokers
Wang, Z., Faith, M., Patterson, F., Tang, K., Kerrin, K., Wileyto, E. P., Detre, J. A., & Lerman, C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2966-07.2007 · Cited by 256
Self-citationMolecular correlates of age-dependent seizures in an inherited neonatal-infantile epilepsy
Liao, Y., Deprez, L., Maljevic, S., Pitsch, J., Claes, L., Hristova, D., Jordanova, A., Ala-Mello, S., Bellan-Koch, A., Blazevic, D., et al. (2010) · Brain · doi:10.1093/brain/awq057 · Cited by 185
Wang, D. J. J., Rao, H., Korczykowski, M., Wintering, N., Pluta, J., Khalsa, D. S., & Newberg, A. B. (2011) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2010.09.011 · Cited by 122
Acute stress modulates genotype effects on amygdala processing in humans
Cousijn, H., Rijpkema, M., Qin, S., van Marle, H. J. F., Franke, B., Hermans, E. J., van Wingen, G., & Fernández, G. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003514107 · Cited by 115
Metadata
- Authors
- Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A.
- Venue
- Radiology
- Published
- 2005-04
- Volume
- 235
- Issue
- 1
- Pages
- 218-228
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2106706293
- Cited by
- 271
- References
- 2
- FWCI
- 12.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amplitude-modulated Continuous Arterial Spin-labeling 3.0-T Perfusion MR Imaging with a Single Coil: Feasibility Study. https://app.cochat.ai/papers/10.1148/radiol.2351031663
- The paper
- Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005). Amplitude-modulated Continuous Arterial Spin-labeling 3.0-T Perfusion MR Imaging with a Single Coil: Feasibility Study. Radiology. https://doi.org/10.1148/radiol.2351031663
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.