Association between Compliance with Methodological Standards of Diagnostic Research and Reported Test Accuracy: Meta-Analysis of Focused Assessment of US for Trauma
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: To study whether compliance with methodological standards affected the reported accuracy of screening ultrasonography (US) for trauma. MATERIALS AND METHODS: Meta-analysis was conducted of prospective investigations in which US was compared with any diagnostic reference test in patients with suspected abdominal injury. Reports were retrieved from electronic databases without language restrictions; added information was gained with manual search. Two reviewers independently assessed methodological rigor by using 27 items contained in the Standards for Reporting of Diagnostic Accuracy (STARD) checklist and the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Reviews (QUADAS) instrument. Inconsistencies were resolved by means of consensus. Summary receiver operating characteristics and random-effects meta-regression were used to model the effect of methodological standards and other study features on US accuracy. RESULTS: A total of 62 trials, which included a total of 18,167 participants, were eligible for meta-analysis. The average proportion of men or boys was 71.7%, the mean age was 30.6 years +/- 10.8 (standard deviation), and the mean injury severity score was 16.7 +/- 8.3. The prevalence of abdominal trauma was 25.1% (95% confidence interval [CI]: 21.1%, 29.1%). Pooled overall sensitivity and specificity of US were 78.9% (95% CI: 74.9%, 82.9%) and 99.2% (95% CI: 99.0%, 99.4%), respectively. Varying end points (hemoperitoneum or organ damage) did not change these results. US accuracy was much lower in children (sensitivity, 57.9%; specificity, 94.3%). Strong heterogeneity was observed in sensitivity, whereas specificity remained constant across trials. There was evidence of publication bias. Initial interobserver agreement with methodological standards ranged from poor (kappa = 0.03, independent verification of US findings) to perfect (kappa = 1.00, sufficiently short interval between US and reference test). By consensus, studies fulfilled a median of 13 methodological criteria (range, five to 20 criteria). In investigations that lacked individual methodological standards, researchers overestimated pooled sensitivity, with predicted differences of 9%-18%. The use of a single reference test, specification of the number of excluded patients, and calculation of CIs independently contributed to predicted sensitivity in a multivariate model. In 16 investigations (1309 subjects), a single reference test was used, which provided a combined sensitivity of 66.0% (95% CI: 56.2%, 75.8%). CONCLUSION: Bias-adjusted sensitivity of screening US for trauma is low. Adherence to methodological standards included in appraisal instruments like STARD and QUADAS is crucial to obtain valid estimates of test accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
How should meta‐regression analyses be undertaken and interpreted?
Thompson, S. G., & Higgins, J. P. T. (2002) · Statistics in Medicine · doi:10.1002/sim.1187 · Cited by 3,026
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Kunz, R., & Oxman, A. D. (1998) · BMJ · doi:10.1136/bmj.317.7167.1185 · Cited by 770
Meta-analysis of screening and diagnostic tests.
Hasselblad, V., & Hedges, L. V. (1995) · Psychological Bulletin · doi:10.1037/0033-2909.117.1.167 · Cited by 579
Greenland, S. (2001) · Biostatistics · doi:10.1093/biostatistics/2.4.463 · Cited by 359
MacLehose, Reeves, Harvey, Sheldon, Russell, & Black (2000) · Health Technology Assessment · doi:10.3310/hta4340 · Cited by 311
Greenland, S. (1994) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117250 · Cited by 150
Cited by
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
“For example, a higher ultrasonography transducer frequency has been shown to improve sensitivity for the evaluation of patients with abdominal trauma (13).”
BackgroundRossaint, R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Filipescu, D., Hunt, B. J., Komadina, R., Nardi, G., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1265-x · Cited by 1,484
Spahn, D. R., Bouillon, B., Cerny, V., Duranteau, J., Filipescu, D., Hunt, B. J., Komadina, R., Maegele, M., Nardi, G., Riddez, L., et al. (2019) · Critical Care · doi:10.1186/s13054-019-2347-3 · Cited by 1,269
Management of bleeding and coagulopathy following major trauma: an updated European guideline
Spahn, D. R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Filipescu, D., Hunt, B. J., Komadina, R., Nardi, G., et al. (2013) · Critical Care · doi:10.1186/cc12685 · Cited by 977
Management of bleeding following major trauma: an updated European guideline
Rossaint, R., Bouillon, B., Cerny, V., Coats, T. J., Duranteau, J., Fernández-Mondéjar, E., Hunt, B. J., Komadina, R., Nardi, G., Neugebauer, E., et al. (2010) · Critical Care · doi:10.1186/cc8943 · Cited by 818
Metadata
- Authors
- Stengel, D., Bauwens, K., Rademacher, G., Mutze, S., & Ekkernkamp, A.
- Venue
- Radiology
- Published
- 2005-07
- Volume
- 236
- Issue
- 1
- Pages
- 102-111
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137104406
- Cited by
- 75
- References
- 10
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Association between Compliance with Methodological Standards of Diagnostic Research and Reported Test Accuracy: Meta-Analysis of Focused Assessment of US for Trauma. https://app.cochat.ai/papers/10.1148/radiol.2361040791
- The paper
- Stengel, D., Bauwens, K., Rademacher, G., Mutze, S., & Ekkernkamp, A. (2005). Association between Compliance with Methodological Standards of Diagnostic Research and Reported Test Accuracy: Meta-Analysis of Focused Assessment of US for Trauma. Radiology. https://doi.org/10.1148/radiol.2361040791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.