Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults

Menke, Jan·2005·Radiology

Abstract

PURPOSE: To investigate prospectively which of several body size parameters are suitable for individual dose adaptation in body computed tomography (CT) of adults. MATERIALS AND METHODS: Three body regions (thorax, abdomen, pelvis) were scanned exclusively for clinical reasons, with institutional ethical approval and informed consent. For each of the three regions, 50 men and 50 women (aged 18-87 years) were studied (300 scans total). Individual x-ray properties for each scan were summarized with a water-equivalent diameter (Dw). Different body size parameters, based on weight, height, and shape, were correlated with Dw by using regression analysis. This resulted in Dw estimation errors of different magnitudes, indicated with 95% prediction intervals. The errors from weight were compared with those from each of the other body parameters by using comparison of variance in paired samples (P < .05). In addition, a topogram-based estimate for Dw was studied, which simulated an automated body size measurement. RESULTS: For the thorax, abdomen, and pelvis, mean Dw was 28.0, 29.1, and 29.3 cm, and estimation of Dw from weight enabled 95% prediction intervals of +/-2.5, +/-2.4, and +/-2.6 cm, respectively. Combinations of height and weight were only slightly more or even less exact than were measurements from only weight. Diameter-related parameters such as body circumference were similar to or better than weight. However, the topogram-based estimate was significantly more exact. CONCLUSION: Body weight and circumference enable suitable estimates for individual dose adaptation in body CT of adults if automated dose adaptation is not available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2362041327

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 164

Metadata

Authors
Menke, J.
Venue
Radiology
Published
2005-08
Volume
236
Issue
2
Pages
565-571
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2030673016
Cited by
164
References
1
FWCI
2.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults. https://app.cochat.ai/papers/10.1148/radiol.2362041327
The paper
Menke, J. (2005). Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults. Radiology. https://doi.org/10.1148/radiol.2362041327

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.