Comparison of Different Body Size Parameters for Individual Dose Adaptation in Body CT of Adults
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate prospectively which of several body size parameters are suitable for individual dose adaptation in body computed tomography (CT) of adults. MATERIALS AND METHODS: Three body regions (thorax, abdomen, pelvis) were scanned exclusively for clinical reasons, with institutional ethical approval and informed consent. For each of the three regions, 50 men and 50 women (aged 18-87 years) were studied (300 scans total). Individual x-ray properties for each scan were summarized with a water-equivalent diameter (Dw). Different body size parameters, based on weight, height, and shape, were correlated with Dw by using regression analysis. This resulted in Dw estimation errors of different magnitudes, indicated with 95% prediction intervals. The errors from weight were compared with those from each of the other body parameters by using comparison of variance in paired samples (P < .05). In addition, a topogram-based estimate for Dw was studied, which simulated an automated body size measurement. RESULTS: For the thorax, abdomen, and pelvis, mean Dw was 28.0, 29.1, and 29.3 cm, and estimation of Dw from weight enabled 95% prediction intervals of +/-2.5, +/-2.4, and +/-2.6 cm, respectively. Combinations of height and weight were only slightly more or even less exact than were measurements from only weight. Diameter-related parameters such as body circumference were similar to or better than weight. However, the topogram-based estimate was significantly more exact. CONCLUSION: Body weight and circumference enable suitable estimates for individual dose adaptation in body CT of adults if automated dose adaptation is not available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Computerized transverse axial scanning (tomography): Part 2. Clinical application*
Ambrose, J. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1023 · Cited by 840
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Greess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Effective doses to patients undergoing thoracic computed tomography examinations
Huda, W., Scalzetti, E. M., & Roskopf, M. L. (2000) · Medical Physics · doi:10.1118/1.598949 · Cited by 144
Radiation Dose Management: Weighing Risk Versus Benefit
Haaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Cited by
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Marin, D., Nelson, R. C., Schindera, S. T., Richard, S., Youngblood, R. S., Yoshizumi, T. T., & Samei, E. (2010) · Radiology · doi:10.1148/radiol.09090094 · Cited by 484
Radiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256
CT Radiation Dose Optimization and Estimation: an Update for Radiologists
Goo, H. W. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.1.1 · Cited by 252
“An attenuation-based parameter using a scout has been used in other studies (20, 21).”
MethodMcCollough, C., Bakalyar, D., Bostani, M., Brady, S., Boedeker, K., Boone, J., Chen-Mayer, H. H., Christianson, O., Leng, S., Li, B., et al. (2014) · doi:10.37206/146 · Cited by 171
“Previous work has expressed the x-ray attenuation of a patient in terms of a water cylinder having the same x-ray absorption [5-9].”
BackgroundMethodSchindera, S. T., Odedra, D., Raza, S. A., Kim, T. K., Jang, H.-J., Szucs-Farkas, Z., & Rogalla, P. (2013) · Radiology · doi:10.1148/radiol.13122349 · Cited by 159
Metadata
- Authors
- Menke, J.
- Venue
- Radiology
- Published
- 2005-08
- Volume
- 236
- Issue
- 2
- Pages
- 565-571
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2030673016
- Cited by
- 164
- References
- 16
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.