CoChat

Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization

Li, Feng, Arimura, Hidetaka, Suzuki, Kenji, Shiraishi, Junji, Li, Qiang, Abe, Hiroyuki, Engelmann, Roger, Sone, Shusuke, MacMahon, Heber, Doi, Kunio · 2005 · Radiology
Cited by 118

The DOI matches its Crossref record.

Abstract

PURPOSE: To retrospectively evaluate whether a difference-image computer-aided detection (CAD) scheme can help radiologists detect peripheral lung cancers missed at low-dose computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed patient and observer consent were obtained. Seventeen patients (eight men and nine women; mean age, 60 years) with a missed peripheral lung cancer and 10 control subjects (five men and five women; mean age, 63 years) without cancer at low-dose CT were included in an observer study. Fourteen radiologists were divided into two groups on the basis of different image display formats: Six radiologists (group 1) reviewed CT scans with a multiformat display, and eight radiologists (group 2) reviewed images with a "stacked" cine-mode display. The radiologists, first without and then with the CAD scheme, indicated their confidence level regarding the presence (or absence) of cancer and the most likely position of a lesion on each CT scan. Receiver operating characteristic (ROC) curves were calculated without and with localization to evaluate the observers' performance. RESULTS: With the CAD scheme, the average area under the ROC curve improved from 0.763 to 0.854 for all radiologists (P = .002), from 0.757 to 0.862 for group 1 (P = .04), and from 0.768 to 0.848 for group 2 (P = .01). The average sensitivity in the detection of 17 cancers improved from 52% (124 of 238 observations) to 68% (163 of 238 observations) for all radiologists (P < .001), from 49% (50 of 102 observations) to 71% (72 of 102 observations) for group 1 (P = .02), and from 54% (74 of 136 observations) to 67% (91 of 136 observations) for group 2 (P = .006). The localization ROC curve also improved. CONCLUSION: Lung cancers missed at low-dose CT were very difficult to detect, even in an observer study. The use of CAD, however, can improve radiologists' performance in the detection of these subtle cancers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2372041555

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Li, F., Arimura, H., Suzuki, K., Shiraishi, J., Li, Q., Abe, H., Engelmann, R., Sone, S., MacMahon, H., & Doi, K.
Venue
Radiology
Published
2005-11
Volume
237
Issue
2
Pages
684-690
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2170698529
Cited by
118
References
0
FWCI
7.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization. https://app.cochat.ai/papers/10.1148/radiol.2372041555
The paper
Li, F., Arimura, H., Suzuki, K., Shiraishi, J., Li, Q., Abe, H., Engelmann, R., Sone, S., MacMahon, H., & Doi, K. (2005). Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization. Radiology. https://doi.org/10.1148/radiol.2372041555

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.