CoChat

Corrected Tetralogy of Fallot: Delayed Enhancement in Right Ventricular Outflow Tract

Oosterhof, Thomas, Mulder, Barbara J. M., Vliegen, Hubert W., de Roos, Albert · 2005 · Radiology
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate retrospectively the presence of fibrosis and largest diameter of the right ventricular outflow tract (RVOT) by using delayed enhancement magnetic resonance (MR) imaging in patients who had undergone initial correction for tetralogy of Fallot. MATERIALS AND METHODS: MR imaging was performed in 24 consecutive patients (16 male, eight female; mean age, 25 years; age range, 13-47 years) with corrected tetralogy of Fallot. The study protocol was approved by the local ethics committee, and informed consent was not required. Fifteen minutes after injection of 0.2 mmol/kg gadopentetate dimeglumine, an inversion-recovery turbo field-echo sequence was applied for detection of delayed enhancement. Right ventricular volumes, ejection fraction, and anterior-posterior diameter of the RVOT were calculated. Mann-Whitney nonparametric testing was used to compare measurements of ventricular volume, function, and anterior-posterior diameter of the RVOT in the presence or absence of delayed enhancement. Correlation was tested with Pearson coefficient. RESULTS: Delayed enhancement was seen in 17 patients in the RVOT. During initial surgery, transannular patching was performed in 13 (76%) of 17 patients, RVOT patching in one (6%) of 17 patients, and the Brock procedure in two (12%) of 17 patients. In one patient, the type of initial RVOT repair was unknown. Patients with delayed enhancement in the RVOT, as compared with those without delayed enhancement in the RVOT, had increased RVOT diameter (32 mm +/- 7 [standard deviation] vs 22 mm +/- 3, P < .01), decreased right ventricular ejection fraction (43% +/- 6.3 vs 54% +/- 10, P < .001), and increased end-diastolic volume (175 mL/m2 +/- 42 vs 118 mL/m2 +/- 34, P < .01). The diameter of the RVOT correlated with increased right ventricular end-systolic volume (R = 0.86) and was inversely related to ejection fraction (R = -0.65). CONCLUSION: Delayed enhancement occurs frequently in patients after correction for tetralogy of Fallot. Delayed enhancement in the RVOT was associated with RVOT dilatation, which adversely affects right ventricular hemodynamics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2373041324

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 107

Metadata

Authors
Oosterhof, T., Mulder, B. J. M., Vliegen, H. W., & de Roos, A.
Venue
Radiology
Published
2005-12
Volume
237
Issue
3
Pages
868-871
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1975284627
Cited by
107
References
1
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corrected Tetralogy of Fallot: Delayed Enhancement in Right Ventricular Outflow Tract. https://app.cochat.ai/papers/10.1148/radiol.2373041324
The paper
Oosterhof, T., Mulder, B. J. M., Vliegen, H. W., & de Roos, A. (2005). Corrected Tetralogy of Fallot: Delayed Enhancement in Right Ventricular Outflow Tract. Radiology. https://doi.org/10.1148/radiol.2373041324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.