Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Quantification of Diffuse Myocardial Fibrosis and Its Association With Myocardial Dysfunction in Congenital Heart Disease

Open access
Broberg, Craig S., Chugh, Sumeet S., Conklin, Catherine, Sahn, David J., Jerosch-Herold, Michael·2010·Circulation: Cardiovascular Imaging

Abstract

Background—: The etiology of ventricular dysfunction in adult congenital heart disease (ACHD) is not well understood. Diffuse fibrosis is a likely common final pathway and is quantifiable using MRI. Methods and Results—: Patients with ACHD (n=50) were studied with cardiac MRI to quantify systemic ventricular volume and function and diffuse fibrosis. The fibrosis index for a single midventricular plane of the systemic ventricle was quantified by measuring T1 values for blood pool and myocardium before and after administration of gadolinium (0.15 mmol/kg) and then adjusted for hematocrit. Results were compared to healthy volunteers (normal controls, n=14) and patients with acquired heart failure (positive controls, n=4). Patients studied (age, 37±12 years; female sex, 40%) included 11 with a systemic right ventricle (RV), 17 with tetralogy of Fallot, 10 with cyanosis, and 12 with other lesions. The fibrosis index was significantly elevated in patients with ACHD compared to normal controls (31.9±4.9% versus 24.8±2.0%; P =0.001). Values were highest in patients with a systemic RV (35.0±5.8%; P <0.001) and those who were cyanotic (33.7±5.6%; P <0.001). The fibrosis index correlated with end-diastolic volume index ( r =0.60; P <0.001) and ventricular ejection fraction ( r =−0.53; P <0.001) but not with age or oxygen saturation in patients who were cyanotic. Late gadolinium enhancement did not account for the differences seen. Conclusions—: Patients with ACHD have evidence of diffuse, extracellular matrix remodeling similar to patients with acquired heart failure. The fibrosis index may facilitate studies on the mechanisms and treatment of myocardial fibrosis and heart failure in these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.108.842096

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 262

Metadata

Authors
Broberg, C. S., Chugh, S. S., Conklin, C., Sahn, D. J., & Jerosch-Herold, M.
Venue
Circulation: Cardiovascular Imaging
Published
2010-11
Volume
3
Issue
6
Pages
727-734
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2124094285
Cited by
262
References
33
FWCI
15.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Diffuse Myocardial Fibrosis and Its Association With Myocardial Dysfunction in Congenital Heart Disease. https://app.cochat.ai/papers/10.1161/circimaging.108.842096
The paper
Broberg, C. S., Chugh, S. S., Conklin, C., Sahn, D. J., & Jerosch-Herold, M. (2010). Quantification of Diffuse Myocardial Fibrosis and Its Association With Myocardial Dysfunction in Congenital Heart Disease. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.108.842096

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.