Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research Network
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively investigate the factors--including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit--affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS: The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20-29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS: Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (+/- their standard errors) were 0.77 +/- 0.05 at 1.5 T, 0.90 +/- 0.09 at 3.0 T, and 0.95 +/- 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION: MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335
Self-citation
Cited by
Shenton, M. E., Hamoda, H. M., Schneiderman, J. S., Bouix, S., Pasternak, O., Rathi, Y., Vu, M.-A., Purohit, M. P., Helmer, K., Koerte, I., et al. (2012) · Brain Imaging and Behavior · doi:10.1007/s11682-012-9156-5 · Cited by 941
Self-citationHow reliable are the results from functional magnetic resonance imaging?
Bennett, C. M., & Miller, M. B. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05446.x · Cited by 577
Salimi-Khorshidi, G., Smith, S. M., Keltner, J. R., Wager, T. D., & Nichols, T. E. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.039 · Cited by 388
White, T., Blok, E., & Calhoun, V. D. (2022) · Human Brain Mapping · doi:10.1002/hbm.25120 · Cited by 176
The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2500-8 · Cited by 94
Metadata
- Authors
- Zou, K. H., Greve, D. N., Wang, M., Pieper, S. D., Warfield, S. K., White, N. S., Manandhar, S., Brown, G. G., Vangel, M. G., Kikinis, R., & Wells, W. M.
- Venue
- Radiology
- Published
- 2005-12
- Volume
- 237
- Issue
- 3
- Pages
- 781-789
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1966946893
- Cited by
- 94
- References
- 1
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research Network. https://app.cochat.ai/papers/10.1148/radiol.2373041630
- The paper
- Zou, K. H., Greve, D. N., Wang, M., Pieper, S. D., Warfield, S. K., White, N. S., Manandhar, S., Brown, G. G., Vangel, M. G., Kikinis, R., & Wells, W. M. (2005). Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research Network. Radiology. https://doi.org/10.1148/radiol.2373041630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.