The DOI matches its Crossref record; 61 of the 62 references it cites were found in a registry or an index, and 1 are not checked yet.
A systematic review of the utility of 1·5 versus 3 Tesla magnetic resonance brain imaging in clinical practice and research
Abstract
Objective MRI at 3 T is said to be more accurate than 1.5 T MR, but costs and other practical differences mean that it is unclear which to use.Methods We systematically reviewed studies comparing diagnostic accuracy at 3 T with 1.5 T. We searched MEDLINE, EMBASE and other sources from 1 January 2000 to 22 October 2010 for studies comparing diagnostic accuracy at 1.5 and 3 T in human neuroimaging. We extracted data on methodology, quality criteria, technical factors, subjects, signal-to-noise, diagnostic accuracy and errors according to QUADAS and STARD criteria.Results Amongst 150 studies (4,500 subjects), most were tiny, compared old 1.5 T with new 3 T technology, and only 22 (15 %) described diagnostic accuracy. The 3 T images were often described as "crisper", but we found little evidence of improved diagnosis. Improvements were limited to research applications [functional MRI (fMRI), spectroscopy, automated lesion detection]. Theoretical doubling of the signal-to-noise ratio was not confirmed, mostly being 25 %. Artefacts were worse and acquisitions took slightly longer at 3 T.Conclusion Objective evidence to guide MRI purchasing decisions and routine diagnostic use is lacking. Rigorous evaluation accuracy and practicalities of diagnostic imaging technologies should be the routine, as for pharmacological interventions, to improve effectiveness of healthcare.Key points • Higher field strength MRI may improve image quality and diagnostic accuracy. • There are few direct comparisons of 1.5 and 3 T MRI. • Theoretical doubling of the signal-to-noise ratio in practice was only 25 %. • Objective evidence of improved routine clinical diagnosis is lacking. • Other aspects of technology improved images more than field strength.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A field strength of 3·0 T might be preferred, but images from modern 1·5 T MRI scanners are often of a similarly high definition,80 and are therefore acceptable”
From Neuroimaging standards for research into small vessel disease and its contribution to ageing and neurodegeneration (2013) · cites this paper as [80]
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging
Haacke, E. M., Makki, M., Ge, Y., Maheshwari, M., Sehgal, V., Hu, J., Selvan, M., Wu, Z., Latif, Z., Xuan, Y., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21676 · Cited by 329 · cited 1×
“Of the 22 studies (15 %) that did provide some sensitivity and specificity information, 7 calculated accuracy on a per patient basis [17, 26–31], 9 calculated accuracy on a per lesion basis [32–40], 4 calculated both [16, 41–43] and in two studies, sensitivity and specificity were irrelevant [44, 45], precluding a for…”
BackgroundfMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes
van der Zwaag, W., Francis, S., Head, K., Peters, A., Gowland, P., Morris, P., & Bowtell, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.015 · Cited by 281
Comparison of 18F-FET PET and 5-ALA fluorescence in cerebral gliomas
Floeth, F. W., Sabel, M., Ewelt, C., Stummer, W., Felsberg, J., Reifenberger, G., Steiger, H. J., Stoffels, G., Coenen, H. H., & Langen, K.-J. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1690-z · Cited by 281
3T phased array MRI improves the presurgical evaluation in focal epilepsies: A prospective study
Knake, S., Triantafyllou, C., Wald, L. L., Wiggins, G., Kirk, G. P., Larsson, P. G., Stufflebeam, S. M., Foley, M. T., Shiraishi, H., Dale, A. M., et al. (2005) · Neurology · doi:10.1212/01.wnl.0000179355.04481.3c · Cited by 225
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
Research works printed but not linked: 1
- Wellcome Trust (2011) Human functional brain imaging 1990–2009: portfolio review. Wellcome Trust, London
Cited by
Wardlaw, J. M., Smith, E. E., Biessels, G. J., Cordonnier, C., Fazekas, F., Frayne, R., Lindley, R. I., O'Brien, J. T., Barkhof, F., Benavente, O. R., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70124-8 · Cited by 5,544
Self-citationWhat are White Matter Hyperintensities Made of?: Relevance to Vascular Cognitive Impairment
Wardlaw, J. M., Valdés Hernández, M. C., & Muñoz‐Maniega, S. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.114.001140 · Cited by 902
Self-citationSmith, E. E., Saposnik, G., Biessels, G. J., Doubal, F. N., Fornage, M., Gorelick, P. B., Greenberg, S. M., Higashida, R. T., Kasner, S. E., & Seshadri, S. (2017) · Stroke · doi:10.1161/str.0000000000000116 · Cited by 404
Clancy, Ú., Gilmartin, D., Jochems, A. C. C., Knox, L., Doubal, F., & Wardlaw, J. M. (2021) · The Lancet Psychiatry · doi:10.1016/s2215-0366(20)30431-4 · Cited by 180
Self-citationClinical Impact of Deep Learning Reconstruction in MRI
Kiryu, S., Akai, H., Yasaka, K., Tajima, T., Kunimatsu, A., Yoshioka, N., Akahane, M., Abe, O., & Ohtomo, K. (2023) · Radiographics · doi:10.1148/rg.220133 · Cited by 180
Metadata
- Authors
- The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., Morris, Z., Pernet, C., Nailon, W., Ahearn, T., Mumuni, A. N., Mugruza, C., McLean, J., Chakirova, G., Tao, Y., Simpson, J., Stanfield, A. C., Johnston, H., Parikh, J., Royle, N. A., De Wilde, J., Bastin, M. E., Weir, N., Farrall, A., & Valdes Hernandez, M. C.
- Affiliations
- Western General Hospital (GB)
- University of Edinburgh (GB)
- University of Dundee (GB)
- University of Aberdeen (GB)
- University of Glasgow (GB)
- University of Stirling (GB)
- University of St Andrews (GB)
- Higher Education Academy (GB)
- Edinburgh Royal Infirmary (GB)
- Corresponding author
- Wardlaw, Joanna M.
- ORCID
- Venue
- European Radiology
- Published
- 2012-06-09
- Volume
- 22
- Issue
- 11
- Pages
- 2295-2303
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W1964031016
- Cited by
- 94
- References
- 61
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 8 · 2020: 7 · 2019: 4 · 2018: 5 · 2017: 9 · 2016: 9 · 2015: 8 · 2014: 7 · 2013: 2 · 2012: 3
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- Discovery Research Portal (University of Dundee) (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- 3T MRI, 1.5T MRI, brain MRI, diagnostic accuracy, signal-to-noise ratio, image artifacts, functional MRI, MRI spectroscopy, automated lesion detection, MRI field strength
- MeSH terms
- Brain, Brain Mapping, Diagnostic Imaging, Humans, Magnetic Resonance Imaging, Multiple Sclerosis, Neoplasms, Predictive Value of Tests, Research Design, Reproducibility of Results, Biomedical Research, Signal-To-Noise Ratio, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A systematic review of the utility of 1·5 versus 3 Tesla magnetic resonance brain imaging in clinical practice and research. https://app.cochat.ai/papers/10.1007/s00330-012-2500-8
- The paper
- The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., Morris, Z., Pernet, C., Nailon, W., Ahearn, T., Mumuni, A. N., Mugruza, C., McLean, J., Chakirova, G., Tao, Y., . . . Valdes Hernandez, M. C. (2012). A systematic review of the utility of 1·5 versus 3 Tesla magnetic resonance brain imaging in clinical practice and research. European Radiology. https://doi.org/10.1007/s00330-012-2500-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.