Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise
Abstract
PURPOSE: To prospectively investigate the effect of low tube voltage on radiation dose, contrast enhancement, image quality, and image noise at abdominal dynamic computed tomography (CT). MATERIALS AND METHODS: The institutional review board approved this study. Prior informed consent was obtained from all patients. Forty patients (24 women, 16 men; mean age, 62 years) underwent initial abdominal CT at 120 kV with 100 mL of contrast material (protocol A). Then all patients were randomly assigned to one of two protocols (protocol B, CT at 90 kV with 100 mL contrast material; protocol C, CT at 90 kV with 80 mL contrast material). The CT numbers of their abdominal organs were assessed quantitatively and qualitatively. Statistical analysis was performed by using the two-tailed paired t test, Kruskal-Wallis test, and kappa test of interobserver agreement. The radiation dose was measured with a phantom that consisted of glass-rod dosimeters. RESULTS: Quantitative analysis revealed that protocols B and C yielded significantly better enhancement of the aorta, liver, pancreas, spleen, and kidney than did protocol A (P < .05). With qualitative analysis, the difference among the three protocols in regard to image quality was not significant. At 90 kV versus 120 kV, the radiation dose reduction in the center of the phantom was 56.8% (6.3 vs 14.6 mGy); in the periphery, it was 46.2% (13.6 vs 25.3 mGy). CONCLUSION: By decreasing the tube voltage, the amount of contrast material can be reduced without image quality degradation. In scans obtained with a low tube voltage, the radiation dose can be reduced as much as 56.8%, and higher contrast material enhancement can be achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cited by
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Dual-Energy CT: General Principles
Johnson, T. R. C. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9116 · Cited by 631
Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
Leschka, S., Stolzmann, P., Schmid, F. T., Scheffel, H., Stinn, B., Marincek, B., Alkadhi, H., & Wildermuth, S. (2008) · European Radiology · doi:10.1007/s00330-008-0966-1 · Cited by 290
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48
Metadata
- Authors
- Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., & Yamashita, Y.
- Venue
- Radiology
- Published
- 2005-12
- Volume
- 237
- Issue
- 3
- Pages
- 945-951
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2068943123
- Cited by
- 422
- References
- 2
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise. https://app.cochat.ai/papers/10.1148/radiol.2373041655
- The paper
- Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., & Yamashita, Y. (2005). Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise. Radiology. https://doi.org/10.1148/radiol.2373041655
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.