The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Dual-Energy CT: General Principles
Abstract
OBJECTIVE: In dual-energy CT (DECT), two CT datasets are acquired with different x-ray spectra. These spectra are generated using different tube potentials, partially also with additional filtration at 140 kVp. Spectral information can also be resolved by layer detectors or quantum-counting detectors. Several technical approaches-that is, sequential acquisition, rapid voltage switching, dual-source CT (DSCT), layer detector, quantum-counting detector-offer different spectral contrast and dose efficiency. Various postprocessing algorithms readily provide clinically relevant spectral information. CONCLUSION: DECT offers the possibility to exploit spectral information for diagnostic purposes. There are different technical approaches, all of which have inherent advantages and disadvantages, especially regarding spectral contrast and dose efficiency. There are numerous clinical applications of DECT that are easily accessible with specific postprocessing algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Self-citationMetal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537
Self-citationAtherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., et al. (2005) · Radiology · doi:10.1148/radiol.2373041655 · Cited by 422
Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Self-citationShikhaliev, P. M., & Fritz, S. G. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/7/001 · Cited by 190
Selective iodine imaging using K‐edge energies in computerized x‐ray tomography
Riederer, S. J., & Mistretta, C. A. (1977) · Medical Physics · doi:10.1118/1.594357 · Cited by 153
Relative properties of tomography, K‐edge imaging, and K‐edge tomography
Kruger, R. A., Riederer, S. J., & Mistretta, C. A. (1977) · Medical Physics · doi:10.1118/1.594374 · Cited by 57
Dual Energy CT Application in the Abdomen
Bolus, D. N. (2013) · Current Radiology Reports · doi:10.1007/s40134-013-0024-x · Cited by 5
Cited by
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48
Metadata
- Authors
- Johnson, T. R. C.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2012-11
- Volume
- 199
- Issue
- 5_supplement
- Pages
- S3-S8
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2136281361
- Cited by
- 631
- References
- 9
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Energy CT: General Principles. https://app.cochat.ai/papers/10.2214/ajr.12.9116
- The paper
- Johnson, T. R. C. (2012). Dual-Energy CT: General Principles. American Journal of Roentgenology. https://doi.org/10.2214/ajr.12.9116
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.