MR Imaging in Patients with Crohn Disease: Value of T2- versus T1-weighted Gadolinium-enhanced MR Sequences with Use of an Oral Superparamagnetic Contrast Agent
Abstract
PURPOSE: To prospectively compare oral contrast-enhanced T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging with T1-weighted gadolinium-enhanced fast low-angle shot (FLASH) MR and standard examinations in the evaluation of Crohn disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Fifty-nine patients with Crohn disease underwent MR imaging after oral administration of a superparamagnetic contrast agent; RARE plain and fat-suppressed sequences and FLASH sequences were performed before and after intravenous injection of gadolinium chelate. References were endoscopic, small-bowel barium, computed tomographic, ultrasonographic, and clinical-biochemical scoring of disease activity. Two radiologists analyzed MR images for presence and extent of Crohn disease lesions, presence of strictures or other complications, and degree of local inflammation. MR findings were correlated with endoscopic, radiologic, and clinical data (kappa statistic and Spearman rank correlation test). RESULTS: T2-weighted MR was 95% accurate, 98% sensitive, and 78% specific for detection of ileal lesions. Agreement between T1- and T2-weighted images ranged from 0.77 for ileal lesions to 1.00 for colic lesions. T2-weighted MR enabled detection of 26 of 29 severe strictures, 17 of 24 enteroenteric fistulas, and all adhesions and abscesses; T1-weighted MR enabled detection of 20 of 29 severe strictures, 16 of 24 enteroenteric fistulas, and all adhesions and abscesses. Complications leading to surgery were found in 12 (20%) patients; these were assessed correctly with either T1- or T2-weighted images. T2-weighted signal intensities of the wall and mesentery correlated with biologic activity (P < .001, r of 0.774 and 0.712, respectively). Interobserver agreement was 0.642-1.00 for T2-weighted and 0.711-1.00 for T1-weighted images. CONCLUSION: T2-weighted MR can depict Crohn disease lesions and help assess mural and transmural inflammation with the same accuracy as gadolinium-enhanced T1-weighted MR. Combination of gadolinium-enhanced T1- and T2-weighted sequences is useful in the assessment of Crohn disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a Crohn's Disease Activity Index
Best, W. R., Becktel, J. M., Singleton, J. W., & Kern, F. (1976) · Gastroenterology · doi:10.1016/s0016-5085(76)80163-1 · Cited by 3,152
Development of a Crohn's disease activity index. National Cooperative Crohn's Disease Study.
Best, W. R., Becktel, J. M., Singleton, J. W., & Kern, F. (1976) · PubMed · Cited by 3,147
Sandborn, W. J., Feagan, B. G., Hanauer, S. B., Lochs, H., Löfberg, R., Modigliani, R., Present, D. H., Rutgeerts, P., Schölmerich, J., Stange, E. F., et al. (2002) · Gastroenterology · doi:10.1053/gast.2002.31072 · Cited by 686
Rederived values of the eight coefficients of the Crohn's Disease Activity Index (CDAI)
Best, W. R., Becktel, J. M., & Singleton, J. W. (1979) · Gastroenterology · doi:10.1016/0016-5085(79)90384-6 · Cited by 562
Cellier, C., Sahmoud, T., Froguel, E., Adenis, A., Belaiche, J., Bretagne, J. F., Florent, C., Bouvry, M., Mary, J. Y., & Modigliani, R. (1994) · Gut · doi:10.1136/gut.35.2.231 · Cited by 430
MR Imaging Evaluation of the Activity of Crohn's Disease
Koh, D. M., Miao, Y., Chinn, R. J. S., Amin, Z., Zeegen, R., Westaby, D., & Healy, J. C. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771325 · Cited by 358
Contrast enhanced magnetic resonance imaging of the terminal ileum in children with Crohn’s disease
Laghi, A., Borrelli, O., Paolantonio, P., Dito, L., de Mesquita, M. B., Falconieri, P., Passariello, R., & Cucchiara, S. (2003) · Gut · doi:10.1136/gut.52.3.393 · Cited by 236
Hahn, P. F., Stark, D. D., Lewis, J. M., Saini, S., Elizondo, G., Weissleder, R., Fretz, C. J., & Ferrucci, J. T. (1990) · Radiology · doi:10.1148/radiology.175.3.2343116 · Cited by 181
Meyers, M. A., & McGuire, P. V. (1995) · Abdominal Imaging · doi:10.1007/bf00203365 · Cited by 179
MR enteroclysis: technical considerations and clinical applications
Gourtsoyiannis, N., Papanikolaou, N. K., Grammatikakis, J., & Prassopoulos, P. K. (2002) · European Radiology · doi:10.1007/s00330-002-1507-y · Cited by 142
Cited by
Van Assche, G., Dignass, A., Panes, J., Beaugerie, L., Karagiannis, J., Allez, M., Ochsenkühn, T., Orchard, T., Rogler, G., Louis, E., et al. (2010) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2009.12.003 · Cited by 1,453
Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn’s disease
Rimola, J., Rodriguez, S., García-Bosch, O., Ordás, I., Ayala, E., Aceituno, M., Pellisé, M., Ayuso, C., Ricart, E., Donoso, L., et al. (2009) · Gut · doi:10.1136/gut.2008.167957 · Cited by 675
Panes, J., Bouhnik, Y., Reinisch, W., Stoker, J., Taylor, S. A., Baumgart, D. C., Danese, S., Halligan, S., Marincek, B., Matos, C., et al. (2013) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2013.02.020 · Cited by 668
Self-citationPanés, J., Bouzas, R., Chaparro, M., García-Sánchez, V., Gisbert, J. P., Martínez de Guereñu, B., Mendoza, J. L., Paredes, J. M., Quiroga, S., Ripollés, T., et al. (2011) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2011.04710.x · Cited by 659
Crohn's disease complicated by strictures: a systematic review
Rieder, F., Zimmermann, E. M., Remzi, F. H., & Sandborn, W. J. (2013) · Gut · doi:10.1136/gutjnl-2012-304353 · Cited by 513
Metadata
- Authors
- Maccioni, F., Bruni, A., Viscido, A., Colaiacomo, M. C., Cocco, A., Montesani, C., Caprilli, R., & Marini, M.
- Venue
- Radiology
- Published
- 2006-02
- Volume
- 238
- Issue
- 2
- Pages
- 517-530
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2171580759
- Cited by
- 275
- References
- 13
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MR Imaging in Patients with Crohn Disease: Value of T2- versus T1-weighted Gadolinium-enhanced MR Sequences with Use of an Oral Superparamagnetic Contrast Agent. https://app.cochat.ai/papers/10.1148/radiol.2381040244
- The paper
- Maccioni, F., Bruni, A., Viscido, A., Colaiacomo, M. C., Cocco, A., Montesani, C., Caprilli, R., & Marini, M. (2006). MR Imaging in Patients with Crohn Disease: Value of T2- versus T1-weighted Gadolinium-enhanced MR Sequences with Use of an Oral Superparamagnetic Contrast Agent. Radiology. https://doi.org/10.1148/radiol.2381040244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.