Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 218

The DOI matches its Crossref record.

Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation

Morton, Marilyn J., Whaley, Dana H., Brandt, Kathleen R., Amrami, Kimberly K.·2006·Radiology

Abstract

PURPOSE: To prospectively determine the effect of a commercially available computer-aided detection (CAD) system on interpretations of screening mammograms. MATERIALS AND METHODS: Institutional review board approval was granted; informed consent and HIPAA compliance were waived. A total of 21 349 screening mammograms obtained in 18 096 women were interpreted first without and then with review of CAD images to determine the effect of CAD analysis on the screening breast cancer detection rate, recall rate, and positive predictive value (PPV) for biopsy. The percentage of total cancers detected by the radiologists independent of CAD and the percentage correctly marked by the CAD system were determined. RESULTS: On the basis of pre-CAD interpretations, 2101 patients were recalled for diagnostic evaluation, 256 biopsies were performed, and 105 breast cancers were diagnosed. The breast cancer detection rate per 1000 screening mammograms was 4.92 (105 of 21 349 mammograms), the recall rate was 9.84% (2101 of 21 349 mammograms), and the PPV for biopsy was 41.0% (105 of 256 biopsies). After CAD image review, 199 additional patients were recalled, 21 additional biopsies were performed, and eight additional cancers were detected. The effect was a 7.62% (eight of 105) increase in the number of breast cancers detected, an increase in the recall rate to 10.77% (2300 of 21 349 mammograms), and a slight decrease in the PPV to 40.8% (113 of 277 biopsies). Radiologists detected 92.9% (105 of 113 cancers) of the total cancers, and CAD correctly marked 76.1% (86 of 113 cancers). CONCLUSION: The use of CAD improved the detection of breast cancer, with an acceptable increase in the recall rate and a minimal increase in the number of biopsies with benign results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2392042121

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 218

Metadata

Authors
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K.
Venue
Radiology
Published
2006-05
Volume
239
Issue
2
Pages
375-383
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2152034657
Cited by
218
References
0
FWCI
17.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation. https://app.cochat.ai/papers/10.1148/radiol.2392042121
The paper
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006). Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation. Radiology. https://doi.org/10.1148/radiol.2392042121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.