The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Transition Zone Prostate Cancers: Features, Detection, Localization, and Staging at Endorectal MR Imaging
Abstract
PURPOSE: To retrospectively evaluate the accuracy of endorectal magnetic resonance (MR) imaging in the detection and local staging of transition zone prostate cancers, with pathologic analysis serving as the reference standard, and to assess MR imaging features of these cancers. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant retrospective study and waived the informed consent requirement. An institutional database of 986 patients who underwent MR imaging before radical prostatectomy yielded 148 consecutive patients with at least one transition zone cancer at step-section pathologic analysis. An additional 46 patients without transition zone cancer were randomly selected as a control group. Two readers independently reviewed MR studies to identify patients with transition zone cancers and determine the location and local extent of these cancers. Imaging features that helped in the identification of transition zone cancers were recorded. Descriptive and kappa statistics, as well as receiver operating characteristic and multivariate logistic regression analyses, were used. RESULTS: For identification of patients with transition zone cancers, sensitivity and specificity were 75% and 87%, respectively, for reader 1 and 80% and 78%, respectively, for reader 2. Interreader agreement was fair. For detection of the location of transition zone cancer, the area under the receiver operating characteristic curve was 0.75 for reader 1 and 0.73 for reader 2. Interreader agreement was fair. The readers' accuracy in detecting transition zone cancer foci increased significantly (P=.001) as tumor volume increased. In the detection of extraprostatic extension of transition zone cancers, sensitivity and specificity were 56% and 94%, respectively, for reader 1 and 28% and 93%, respectively, for reader 2. Homogeneous low T2 signal intensity (P=.001 for reader 1, P<.001 for reader 2) and lenticular shape (P=.017 for reader 1) were significantly associated with the presence of transition zone cancer. CONCLUSION: MR imaging can be used to detect, localize, and stage transition zone prostate cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIAL
CLOPPER, C. J., & PEARSON, E. S. (1934) · Biometrika · doi:10.1093/biomet/26.4.404 · Cited by 5,003
The Statistical Evaluation of Medical Tests for Classification and Prediction
(2005) · Technometrics · doi:10.1198/tech.2005.s278 · Cited by 1,899
McNeal, J. E., Redwine, E. A., Freiha, F. S., & Stamey, T. A. (1988) · The American Journal of Surgical Pathology · doi:10.1097/00000478-198812000-00001 · Cited by 1,182
Nonparametric Analysis of Clustered ROC Curve Data
Obuchowski, N. A. (1997) · Biometrics · doi:10.2307/2533958 · Cited by 429
A New Procedure for Assessing Reliability of Scoring EEG Sleep Recordings
Cicchetti, D. V., & Allison, T. (1971) · American Journal of EEG Technology · doi:10.1080/00029238.1971.11080840 · Cited by 406
McNeal, J. E. (1992) · Human Pathology · doi:10.1016/0046-8177(92)90106-d · Cited by 300
Prostate Cancer Tumor Volume: Measurement with Endorectal MR and MR Spectroscopic Imaging
Coakley, F. V., Kurhanewicz, J., Lu, Y., Jones, K. D., Swanson, M. G., Chang, S. D., Carroll, P. R., & Hricak, H. (2002) · Radiology · doi:10.1148/radiol.2231010575 · Cited by 258
Self-citationPretreatment Evaluation of Prostate Cancer: Role of MR Imaging and1H MR Spectroscopy
Claus, F. G., Hricak, H., & Hattery, R. R. (2004) · RadioGraphics · doi:10.1148/24si045516 · Cited by 158
Self-citationKeetch, D. W., & Catàlona, W. J. (1995) · The Journal of Urology · doi:10.1016/s0022-5347(01)66786-7 · Cited by 116
Cited by
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Prostate Cancer: Multiparametric MR Imaging for Detection, Localization, and Staging
Hoeks, C. M. A., Barentsz, J. O., Hambrock, T., Yakar, D., Somford, D. M., Heijmink, S. W. T. P. J., Scheenen, T. W. J., Vos, P. C., Huisman, H., van Oort, I. M., et al. (2011) · Radiology · doi:10.1148/radiol.11091822 · Cited by 677
de Rooij, M., Hamoen, E. H. J., Witjes, J. A., Barentsz, J. O., & Rovers, M. M. (2016) · European Urology · doi:10.1016/j.eururo.2015.07.029 · Cited by 669
Imaging Prostate Cancer: A Multidisciplinary Perspective
Hricak, H., Choyke, P. L., Eberhardt, S. C., Leibel, S. A., & Scardino, P. T. (2007) · Radiology · doi:10.1148/radiol.2431030580 · Cited by 601
Self-citation
Metadata
- Authors
- Akin, O., Sala, E., Moskowitz, C. S., Kuroiwa, K., Ishill, N. M., Pucar, D., Scardino, P. T., & Hricak, H.
- Venue
- Radiology
- Published
- 2006-06
- Volume
- 239
- Issue
- 3
- Pages
- 784-792
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1980404552
- Cited by
- 379
- References
- 10
- FWCI
- 19.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transition Zone Prostate Cancers: Features, Detection, Localization, and Staging at Endorectal MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2392050949
- The paper
- Akin, O., Sala, E., Moskowitz, C. S., Kuroiwa, K., Ishill, N. M., Pucar, D., Scardino, P. T., & Hricak, H. (2006). Transition Zone Prostate Cancers: Features, Detection, Localization, and Staging at Endorectal MR Imaging. Radiology. https://doi.org/10.1148/radiol.2392050949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.