CoChat

Imaging of Myeloperoxidase in Mice by Using Novel Amplifiable Paramagnetic Substrates

Chen, John W., Querol Sans, Manel, Bogdanov, Alexei, Weissleder, Ralph · 2006 · Radiology
Cited by 153

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate whether contrast agents for molecular magnetic resonance (MR) imaging can demonstrate the in vivo activity of myeloperoxidase, an enzyme that is secreted by stimulated polymorphonuclear leukocytes, monocytes, and macrophages during inflammation. MATERIALS AND METHODS: Animal experiments were approved by the animal care committee. Protocols for the procurement and use of human blood were approved by the institutional review board. Informed consent was obtained from each donor, and HIPAA guidelines were followed for humans. Two paramagnetic myeloperoxidase substrates--that is, gadolinium-5-hydroxytryptamide-tetraazacyclododecane tetraacetic acid (Gd-5-HT-DOTA) and Gd-bis-5-HT-diethylenetriaminepentaacetic acid (Gd-bis-5-HT-DTPA)--were synthesized. Indium 111-labeled bis-5-HT-DTPA was used to determine biodistribution and target localization. A total of 22 mice were used in three models. In the first model, human myeloperoxidase was embedded in a basement membrane matrix gel and was injected intramuscularly. In the second model, lipopolysaccharide (LPS) from Escherichia coli was embedded in a basement membrane matrix gel and was injected intramuscularly to induce endogenous myeloperoxidase secretion. In the third model, LPS was injected intramuscularly to induce myositis. Statistical significance was calculated for contrast-to-noise ratio (CNR) curves by using the Kolmogorov-Smirnov test. RESULTS: After the administration of Gd-bis-5-HT-DTPA, strong MR signal enhancement (up to 2.5-fold increase in CNR, P < .001) was observed in vivo for implants that contained human myeloperoxidase. In the LPS-induced myositis model, a smaller visible difference was seen (1.3-fold increase in CNR, P < .001), which was consistent with the fact that endogenous mouse myeloperoxidase is only about 10%-20% as active as human myeloperoxidase. Prolonged contrast material enhancement was observed in the myeloperoxidase-containing areas that were injected with Gd-5-HT-DOTA or Gd-bis-5-HT-DTPA but was not observed in areas that were injected with Gd-DTPA or Gd-dopamine-DOTA (P < .05). Single photon emission computed tomography combined with computed tomography was used to confirm the increased retention of contrast agents at sites that contained human myeloperoxidase, and the results of biodistribution studies demonstrated a more than fourfold increase radiotracer accumulation at these sites. CONCLUSION: Human and mouse myeloperoxidase activity in myeloperoxidase implants and inflamed tissues can be visualized and reported in vivo by using myeloperoxidase-sensitive "smart" molecular imaging probes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2402050994

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 153

Metadata

Authors
Chen, J. W., Querol Sans, M., Bogdanov, A., & Weissleder, R.
Venue
Radiology
Published
2006-08
Volume
240
Issue
2
Pages
473-481
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2149545411
Cited by
153
References
6
FWCI
8.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).