PURPOSE: To prospectively compare in vivo hepatic automated volumetry with manual volumetry and measured liver volume. MATERIALS AND METHODS: The study was conducted in accordance with the guidelines of the Institutional Review Board of Kumamoto University (Japan). Patient informed consent was obtained. Preoperative multisection computed tomography (CT) was performed in 35 consecutive patients (21 men, 14 women; mean age, 42.8 years; range, 28-72 years) with hepatic disease awaiting living related liver transplantation. The CT scans covered the entire liver at a section thickness of 2.5 mm. Liver volume was estimated by using both the automated and the manual methods. Actual liver weight was obtained for all patients and was converted to hepatic volume on the basis of a predetermined relationship between actual liver weight and volume. Processing time required for both methods was also recorded. Two-tailed paired t test, correlation coefficient, and Bland-Altman tests were used for statistical analyses. RESULTS: Mean liver weight was 881.7 g +/- 249.8 (standard deviation), and mean measured liver volume was 956.00 cm(3) +/- 280.10. Volumetry performed with the automated and manual methods provided liver volumes of 982.99 cm(3) +/- 301.98 and 937.10 cm(3) +/- 301.31, respectively. There was good correlation between measured and estimated volumes obtained with the automated method (r = 0.792, P < .01). The manual and automated methods required 32.8 minutes +/- 6.9 and 4.4 minutes +/- 1.9, respectively. CONCLUSION: The automated method reduced the time required for volumetry of the liver and provided acceptable measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2403050850

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 177

Metadata

Authors
Nakayama, Y., Li, Q., Katsuragawa, S., Ikeda, R., Hiai, Y., Awai, K., Kusunoki, S., Yamashita, Y., Okajima, H., Inomata, Y., & Doi, K.
Venue
Radiology
Published
2006-09
Volume
240
Issue
3
Pages
743-748
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2049377011
Cited by
177
References
3
FWCI
7.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Hepatic Volumetry for Living Related Liver Transplantation At Multisection CT. https://app.cochat.ai/papers/10.1148/radiol.2403050850
The paper
Nakayama, Y., Li, Q., Katsuragawa, S., Ikeda, R., Hiai, Y., Awai, K., Kusunoki, S., Yamashita, Y., Okajima, H., Inomata, Y., & Doi, K. (2006). Automated Hepatic Volumetry for Living Related Liver Transplantation At Multisection CT. Radiology. https://doi.org/10.1148/radiol.2403050850

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.