Cardiac MR Imaging: State of the Technology
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Recent developments in magnetic resonance (MR) imaging of the heart have refocused attention on the potential of MR and continue to attract intense interest within the radiology and cardiology communities. Improvements in speed, image quality, reliability, and range of applications have evolved to the point where cardiac MR imaging is increasingly seen as a practical clinical tool. As is often the case with MR imaging, not all of the most powerful techniques are necessarily easy to master or understand, and many-nonspecialists and specialists alike-are challenged to stay abreast. This review covers some of the major milestones that have led to the current state of cardiac MR and attempts to put into context some concepts that, although technical, have a real impact on the diagnostic power of cardiac MR imaging. Topics discussed include functional imaging, myocardial viability and perfusion imaging, flow quantification, and coronary artery imaging. A review such as this can only scratch the surface of what is a dynamic interdisciplinary field, but the hope is that sufficient information and insight are provided to stimulate the motivated reader to take his or her interest to the next level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bedaux, W. L. F., Hofman, M. B. M., Wielopolski, P. A., de Cock, C. C., Hoffmann, V., Oudkerk, M., de Feyter, P. J., & van Rossum, A. C. (2002) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120003953 · Cited by 14
Cited by
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Steady-State MR Imaging Sequences: Physics, Classification, and Clinical Applications
Chavhan, G. B., Babyn, P. S., Jankharia, B. G., Cheng, H.-L. M., & Shroff, M. M. (2008) · RadioGraphics · doi:10.1148/rg.284075031 · Cited by 294
Cardiac Tumors: Optimal Cardiac MR Sequences and Spectrum of Imaging Appearances
O'Donnell, D. H., Abbara, S., Chaithiraphan, V., Yared, K., Killeen, R. P., Cury, R. C., & Dodd, J. D. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1895 · Cited by 283
Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary Angiography
Kato, S., Kitagawa, K., Ishida, N., Ishida, M., Nagata, M., Ichikawa, Y., Katahira, K., Matsumoto, Y., Seo, K., Ochiai, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.071 · Cited by 262
Undersampled MRI reconstruction with patch-based directional wavelets
Qu, X., Guo, D., Ning, B., Hou, Y., Lin, Y., Cai, S., & Chen, Z. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.02.019 · Cited by 236
“For example, slow imaging speed may lead to motion artifacts in cardiac MRI [1] and abdominal MRI [2] or low spatial resolution in functional MRI [3].”
BackgroundMethod
Metadata
- Authors
- Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G.
- Venue
- Radiology
- Published
- 2006-11
- Volume
- 241
- Issue
- 2
- Pages
- 338-354
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2103284121
- Cited by
- 215
- References
- 1
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.