Enhancement of Vascular Permeability with Low-Frequency Contrast-enhanced Ultrasound in the Chorioallantoic Membrane Model
Abstract
PURPOSE: To characterize the effect of low-frequency contrast material-enhanced ultrasound on the vascular endothelium and to determine the parameters and techniques required to deliver a therapeutic agent by using the chorioallantoic membrane (CAM) model. MATERIALS AND METHODS: All in vivo animal procedures were conducted with institutional Animal Care and Use Committee approval. Extravasation of 8.5-nm-diameter fluorescein isothiocyanate-labeled dextran was evaluated in the vasculature of a chick CAM model. Intravital microscopy was performed during contrast-enhanced ultrasound exposure (1.00 or 2.25 MHz); results were compared with results of electron microscopy of the insonated regions. Data acquired after insonation with greater mechanical stress (n = 30 animals) (mechanical index [MI] > 1.3) and with lower mechanical stress (n = 86 animals) (MI < 1.13) were compared with measurements in control conditions (n = 46 animals). The diameter of affected vessels; number of extravasation sites; extravasation rate, area, and location; and changes in endothelial cells and basement membrane were evaluated. Differences were tested with analysis of variance or the Student t test. RESULTS: After ultrasound application, convective transport of the model drug was observed through micron-sized openings with a mean fluid velocity of 188.6 microm/sec in the low-stress class and 362.5 microm/sec in the high-stress class. Electron microscopy revealed micron-sized focal endothelial gaps and disseminated blebs, vacuoles, and filopodia extending across tens of microns. The threshold pressure for extravasation was 0.5 MPa for a transmitted center frequency of 1.00 MHz (MI = 0.5) and 1.6 MPa for a frequency of 2.25 MHz (MI = 1.06); thus, the frequency dependence of the threshold was not predicted simply by the MI. CONCLUSION: Low-frequency contrast-enhanced ultrasound can increase vascular permeability and result in convective extravasation of an 8.5-nm-diameter model drug.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lipid-Shelled Vehicles: Engineering for Ultrasound Molecular Imaging and Drug Delivery
Ferrara, K. W., Borden, M. A., & Zhang, H. (2009) · Accounts of Chemical Research · doi:10.1021/ar8002442 · Cited by 332
Self-citationUltrasonically triggered drug delivery: Breaking the barrier
Husseini, G. A., Pitt, W. G., & Martins, A. M. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.07.051 · Cited by 87
Cavitation properties of block copolymer stabilized phase-shift nanoemulsions used as drug carriers
Rapoport, N., Christensen, D. A., Kennedy, A. M., & Nam, K.-H. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.11.009 · Cited by 79
Metadata
- Authors
- Stieger, S. M., Caskey, C. F., Adamson, R. H., Qin, S., Curry, F.-R. E., Wisner, E. R., & Ferrara, K. W.
- Venue
- Radiology
- Published
- 2007-04
- Volume
- 243
- Issue
- 1
- Pages
- 112-121
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146749494
- Cited by
- 158
- References
- 0
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhancement of Vascular Permeability with Low-Frequency Contrast-enhanced Ultrasound in the Chorioallantoic Membrane Model. https://app.cochat.ai/papers/10.1148/radiol.2431060167
- The paper
- Stieger, S. M., Caskey, C. F., Adamson, R. H., Qin, S., Curry, F.-R. E., Wisner, E. R., & Ferrara, K. W. (2007). Enhancement of Vascular Permeability with Low-Frequency Contrast-enhanced Ultrasound in the Chorioallantoic Membrane Model. Radiology. https://doi.org/10.1148/radiol.2431060167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.