The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging
Abstract
PURPOSE: To retrospectively identify pulmonary arterial (PA) flow parameters measured with phase-contrast magnetic resonance (MR) imaging that allow noninvasive diagnosis of chronic PA hypertension (PAH). MATERIALS AND METHODS: The study was HIPAA compliant and was approved by the institutional review board; a waiver of informed consent was obtained. Fifty-nine patients (49 female patients; mean age, 46 years; range, 16-85 years) known to have or suspected of having PAH underwent breath-hold phase-contrast MR imaging and right-sided heart catheterization (RHC). The presence of PAH (mean pulmonary artery pressure [mPAP], >25 mm Hg) was confirmed in 42 patients. Parameters, including PA areas, PA strain, average velocity, peak velocity, acceleration time, and ejection time, were measured in each patient by investigators blinded to RHC results. These measurements were correlated with mPAP, systolic pulmonary artery pressure (sPAP), and pulmonary vascular resistance index (PVRI). The diagnostic ability of phase-contrast MR imaging to depict PAH was quantified. Statistical tests included Spearman rho coefficients, receiver operating characteristic curve analysis, and Bland-Altman plots. RESULTS: Results showed average velocity to have the best correlation with mPAP, sPAP, and PVRI (r = -0.73, -0.76, and -0.86, respectively; P < .001). Average velocity (cutoff value = 11.7 cm/sec) revealed PAH with a sensitivity of 92.9% (39 of 42) and a specificity of 82.4% (14 of 17). Sensitivity and specificity for the minimum PA area (cutoff value = 6.6 cm(2)) were 92.9% (39 of 42) and 88.2% (15 of 17), respectively. CONCLUSION: The average blood velocity throughout the cardiac cycle is strongly correlated with pulmonary pressures and resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Obuchowski (2005) · doi:10.2214/ajr.184.2.01840364 · Cited by 321
Cited by
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Optimized 3D ultrashort echo time pulmonary MRI
Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24570 · Cited by 322
Metadata
- Authors
- Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M.
- Venue
- Radiology
- Published
- 2007-04
- Volume
- 243
- Issue
- 1
- Pages
- 70-79
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2049972510
- Cited by
- 227
- References
- 1
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2431060477
- The paper
- Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M. (2007). Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging. Radiology. https://doi.org/10.1148/radiol.2431060477
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.