The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Optimized 3D ultrashort echo time pulmonary MRI
Open accessAbstract
Purpose: To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung imaging. Methods: 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field‐of‐view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phantom studies. Their effects on lung and airway visualization in five healthy male human subjects (mean age 32 years) were compared qualitatively through blinded ordinal scoring by two cardiothoracic radiologists using a nonparametric Friedman test (P < 0.05). Relative signal difference between endobronchial air and adjacent lung tissue, normalized to nearby vessel, was used as a surrogate for lung tissue signal. Quantitative measures were compared using the paired Student's t‐test (P < 0.05). Finally, clinical feasibility was investigated in a patient with interstitial fibrosis. Results: Simulation and phantom studies showed up to 67% improvement in SNR and reduced blurring for short T 2* species using all three optimizations. In vivo images showed decreased artifacts and improved lung tissue and airway visualization both qualitatively and quantitatively. Conclusion: The use of limited field‐of‐view excitation, variable readout gradients, and radial oversampling significantly improve the technical quality of 3D radial ultrashort echo time lung images. Magn Reson Med 70:1241–1250, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Larson, A. C., White, R. D., Laub, G., McVeigh, E. R., Li, D., & Simonetti, O. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10664 · Cited by 419
Simple Correction Method fork-Space Trajectory Deviations in MRI
Duyn, J. H., Yang, Y., Frank, J. A., & van der Veen, J. W. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1396 · Cited by 359
Fast and quiet MRI using a swept radiofrequency
Idiyatullin, D., Corum, C., Park, J.-Y., & Garwood, M. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.05.014 · Cited by 353
Rapid gridding reconstruction with a minimal oversampling ratio
Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848376 · Cited by 333
Barger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10212 · Cited by 291
Sodium MRI using a density‐adapted 3D radial acquisition technique
Nagel, A. M., Laun, F. B., Weber, M., Matthies, C., Semmler, W., & Schad, L. R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22157 · Cited by 287
Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging
Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M. (2007) · Radiology · doi:10.1148/radiol.2431060477 · Cited by 227
MRI with zero echo time: Hard versus sweep pulse excitation
Weiger, M., Pruessmann, K. P., & Hennel, F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22799 · Cited by 201
Self‐calibrating parallel imaging with automatic coil sensitivity extraction
McKenzie, C. A., Yeh, E. N., Ohliger, M. A., Price, M. D., & Sodickson, D. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10087 · Cited by 189
Cited by
Mehranian, A., Arabi, H., & Zaidi, H. (2016) · Medical Physics · doi:10.1118/1.4941014 · Cited by 152
Experimental and quantitative imaging techniques in interstitial lung disease
Weatherley, N. D., Eaden, J. A., Stewart, N. J., Bartholmai, B. J., Swift, A. J., Bianchi, S. M., & Wild, J. M. (2019) · Thorax · doi:10.1136/thoraxjnl-2018-211779 · Cited by 87
Zha, W., Kruger, S. J., Johnson, K. M., Cadman, R. V., Bell, L. C., Liu, F., Hahn, A. D., Evans, M. D., Nagle, S. K., & Fain, S. B. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25877 · Cited by 50
Self-citationHahn, A. D., Carey, K. J., Barton, G. P., Torres, L. A., Kammerman, J., Cadman, R. V., Lee, K. E., Schiebler, M. L., Sandbo, N., & Fain, S. B. (2022) · Radiology · doi:10.1148/radiol.211433 · Cited by 33
Self-citation
Metadata
- Authors
- Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-12-04
- Volume
- 70
- Issue
- 5
- Pages
- 1241-1250
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1925481226
- Cited by
- 322
- References
- 21
- FWCI
- 11.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized 3D ultrashort echo time pulmonary MRI. https://app.cochat.ai/papers/10.1002/mrm.24570
- The paper
- Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S. (2013). Optimized 3D ultrashort echo time pulmonary MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24570
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.