Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Prostate Cancer: Accurate Determination of Extracapsular Extension with High-Spatial-Resolution Dynamic Contrast-enhanced and T2-weighted MR Imaging—Initial Results

Bloch, B. Nicolas, Furman-Haran, Edna, Helbich, Thomas H., Lenkinski, Robert E., Degani, Hadassa, Kratzik, Christian, Susani, Martin, Haitel, Andrea, Jaromi, Silvia, Ngo, Long, Rofsky, Neil M. · 2007 · Radiology

Abstract

PURPOSE: To prospectively compare the sensitivity and specificity of high-spatial-resolution dynamic contrast material-enhanced magnetic resonance (MR) imaging with those of high-spatial-resolution T2-weighted MR imaging, performed with an endorectal coil (ERC), for assessment of extracapsular extension (ECE) and staging in patients with prostate cancer, with histopathologic findings as reference. MATERIALS AND METHODS: The study was approved by the institutional internal review board; a signed informed consent was obtained. MR imaging of the prostate at 1.5 T was performed with combined surface coils and ERCs in 32 patients (mean age, 65 years; range, 42-78 years) before radical prostatectomy. High-spatial-resolution T2-weighted fast spin-echo and high-spatial-resolution dynamic contrast-enhanced three-dimensional gradient-echo images were acquired with gadopentetate dimeglumine. Dynamic contrast-enhanced MR images were analyzed with a computer-generated color-coded scheme. Two experienced readers independently assessed ECE and tumor stage. MR imaging-based staging results were compared with histopathologic results. For the prediction of ECE, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Staging accuracy was determined with the area under the receiver operating characteristic curve (AUC) by using the Wilcoxon-Mann-Whitney index of diagnostic accuracy. RESULTS: The mean sensitivity, specificity, PPV, and NPV for assessment of ECE with the combined data sets for both readers were 86%, 95%, 90%, and 93%, respectively. The sensitivity of MR images for determination of ECE was significantly improved for both readers (>25%) with combined data sets compared with T2-weighted MR images alone. The combined data sets had a mean overall staging accuracy for both readers of 95%, as determined with AUC. Staging results for both readers were significantly improved (P<.05) with the combined data sets compared with T2-weighted MR images alone. CONCLUSION: The combination of high-spatial-resolution dynamic contrast-enhanced MR imaging and T2-weighted MR imaging yields improved assessment of ECE and better results for prostate cancer staging compared with either technique independently.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2451061502

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 234

Metadata

Authors
Bloch, B. N., Furman-Haran, E., Helbich, T. H., Lenkinski, R. E., Degani, H., Kratzik, C., Susani, M., Haitel, A., Jaromi, S., Ngo, L., & Rofsky, N. M.
Venue
Radiology
Published
2007-10
Volume
245
Issue
1
Pages
176-185
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2079799115
Cited by
234
References
3
FWCI
12.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prostate Cancer: Accurate Determination of Extracapsular Extension with High-Spatial-Resolution Dynamic Contrast-enhanced and T2-weighted MR Imaging—Initial Results. https://app.cochat.ai/papers/10.1148/radiol.2451061502
The paper
Bloch, B. N., Furman-Haran, E., Helbich, T. H., Lenkinski, R. E., Degani, H., Kratzik, C., Susani, M., Haitel, A., Jaromi, S., Ngo, L., & Rofsky, N. M. (2007). Prostate Cancer: Accurate Determination of Extracapsular Extension with High-Spatial-Resolution Dynamic Contrast-enhanced and T2-weighted MR Imaging—Initial Results. Radiology. https://doi.org/10.1148/radiol.2451061502

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.