CoChat

CT Colonography with Computer-aided Detection as a Second Reader: Observer Performance Study

Petrick, Nicholas, Haider, Maruf, Summers, Ronald M., Yeshwant, Srinath C., Brown, Linda, Iuliano, Edward M., Louie, Adeline, Choi, J. Richard, Pickhardt, Perry J. · 2008 · Radiology
Cited by 134

The DOI matches its Crossref record.

Abstract

PURPOSE: To evaluate the effect of computer-aided detection (CAD) as second reader on radiologists' diagnostic performance in interpreting computed tomographic (CT) colonographic examinations by using a primary two-dimensional (2D) approach, with segmental, unblinded optical colonoscopy as the reference standard. MATERIALS AND METHODS: This HIPAA-compliant study was IRB-approved with written informed consent. Four board-certified radiologists analyzed 60 CT examinations with a commercially available review system. Two-dimensional transverse views were used for initial polyp detection, while three-dimensional (3D) endoluminal and 2D multiplanar views were available for problem solving. After initial review without CAD, the reader was shown CAD-identified polyp candidates. The readers were then allowed to add to or modify their original diagnoses. Polyp location, CT Colonography Reporting and Data System categorization, and reader confidence as to the likelihood of a candidate being a polyp were recorded before and after CAD reading. The area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, and specificity were estimated for CT examinations with and without CAD readings by using multireader multicase analysis. RESULTS: Use of CAD led to nonsignificant average reader AUC increases of 0.03, 0.03, and 0.04 for patients with adenomatous polyps 6 mm or larger, 6-9 mm, and 10 mm or larger, respectively (P > or = .25); likewise, CAD increased average reader sensitivity by 0.15, 0.16, and 0.14 for those respective groups, with a corresponding decrease in specificity of 0.14. These changes achieved significance for the 6 mm or larger group (P < .01), 6-9 mm group (P < .02), and for specificity (P < .01), but not for the 10 mm or larger group (P > .16). The average reading time was 5.1 minutes +/- 3.4 (standard deviation) without CAD. CAD added an average of 3.1 minutes +/- 4.3 (62%) to each reading (supine and prone positions combined); average total reading time, 8.2 minutes +/- 5.8. CONCLUSION: Use of CAD led to a significant increase in sensitivity for detecting polyps in the 6 mm or larger and 6-9 mm groups at the expense of a similar significant reduction in specificity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2453062161

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 134

Metadata

Authors
Petrick, N., Haider, M., Summers, R. M., Yeshwant, S. C., Brown, L., Iuliano, E. M., Louie, A., Choi, J. R., & Pickhardt, P. J.
Venue
Radiology
Published
2008-01
Volume
246
Issue
1
Pages
148-156
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2150116524
Cited by
134
References
0
FWCI
8.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CT Colonography with Computer-aided Detection as a Second Reader: Observer Performance Study. https://app.cochat.ai/papers/10.1148/radiol.2453062161
The paper
Petrick, N., Haider, M., Summers, R. M., Yeshwant, S. C., Brown, L., Iuliano, E. M., Louie, A., Choi, J. R., & Pickhardt, P. J. (2008). CT Colonography with Computer-aided Detection as a Second Reader: Observer Performance Study. Radiology. https://doi.org/10.1148/radiol.2453062161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.