Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Postinfarction Myocardial Scarring in Mice: Molecular MR Imaging with Use of a Collagen-targeting Contrast Agent

Open access
Helm, Patrick A., Caravan, Peter, French, Brent A., Jacques, Vincent, Shen, Luhua, Xu, Yaqin, Beyers, Ronald J., Roy, R. Jack, Kramer, Christopher M., Epstein, Frederick H.·2008·Radiology

Abstract

PURPOSE: To prospectively evaluate a gadolinium-based collagen-targeting contrast agent, EP-3533, for in vivo magnetic resonance (MR) imaging of myocardial fibrosis in a mouse model of healed myocardial infarction (MI). MATERIALS AND METHODS: All procedures were performed in accordance with protocols approved by the animal care and use committee. MI was induced in eight mice by means of occlusion of the left anterior descending coronary artery followed by reperfusion. Four MR examinations were performed in each animal: one examination before, one examination 1 day after, and two examinations 6 weeks after the MI. For the latter two examinations, electrocardiographically gated inversion-recovery gradient-echo MR images were acquired before and serially (every 5 minutes) after the intravenous injection of either gadopentetate dimeglumine or EP-3533. The image enhancement kinetic properties of the postinfarction scar, normal myocardium, and blood were compared. RESULTS: Dynamic T1-weighted MR imaging revealed the washout time constants for EP-3533 to be significantly longer than those for gadopentetate dimeglumine in regions of postinfarction scarring (mean, 194.8 minutes +/-116.8 [standard deviation] vs 25.5 minutes +/- 4.2; P < .05) and in normal myocardium (mean, 45.4 minutes +/- 16.7 vs 25.1 minutes +/- 9.7; P < .05). Findings on postmortem histologic sections stained for collagen correlated well with EP-3533-enhanced areas seen on inversion-recovery MR images. Fifty minutes after EP-3533 injection, the postinfarction scar tissue samples, as compared with the normal myocardium, had a twofold higher concentration of gadolinium. CONCLUSION: Use of the gadolinium-based collagen-targeting contrast agent, EP-3533, enabled in vivo molecular MR imaging of fibrosis in a mouse model of healed postinfarction myocardial scarring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2473070975

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Helm, P. A., Caravan, P., French, B. A., Jacques, V., Shen, L., Xu, Y., Beyers, R. J., Roy, R. J., Kramer, C. M., & Epstein, F. H.
Venue
Radiology
Published
2008-06
Volume
247
Issue
3
Pages
788-796
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1990428828
Cited by
182
References
0
FWCI
10.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Postinfarction Myocardial Scarring in Mice: Molecular MR Imaging with Use of a Collagen-targeting Contrast Agent. https://app.cochat.ai/papers/10.1148/radiol.2473070975
The paper
Helm, P. A., Caravan, P., French, B. A., Jacques, V., Shen, L., Xu, Y., Beyers, R. J., Roy, R. J., Kramer, C. M., & Epstein, F. H. (2008). Postinfarction Myocardial Scarring in Mice: Molecular MR Imaging with Use of a Collagen-targeting Contrast Agent. Radiology. https://doi.org/10.1148/radiol.2473070975

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.