Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR Imaging
Open accessAbstract
PURPOSE: To develop and evaluate a method based on ultrashort echo-time radial magnetic resonance (MR) imaging to quantify bone water (BW) concentration as a new metric of bone quality in human cortical bone in vivo. MATERIALS AND METHODS: Human subject studies were institutional review board approved and HIPAA compliant; informed consent was obtained. Cortical BW concentration was determined with custom-designed MR imaging sequences at 3.0 T and was validated in sheep and human cortical bone by using exchange of native water with deuterium oxide (D(2)O). The submillisecond T2* of BW requires correction for relaxation losses during the radiofrequency pulse. BW was measured at the tibial midshaft in healthy pre- and postmenopausal women (mean age, 34.6 and 69.4 years, respectively; n = 5 in each group) and in patients receiving maintenance hemodialysis (mean age, 51.8 years; n = 6) and was compared with bone mineral density (BMD) at the same site at peripheral quantitative computed tomography, as well as with BMD of the lumbar spine and hip at dual x-ray absorptiometry. Data were analyzed by using the Pearson correlation coefficient and two-sided t tests as appropriate. RESULTS: Excellent agreement was obtained ex vivo between the water displaced by using D(2)O exchange and water measured with respect to a reference sample (r(2) = 0.99, P < .001). In vivo, BW in the postmenopausal group was greater by 65% (28.7% +/- 1.3 [standard deviation] vs 17.4% +/- 2.2, P < .001) than in the premenopausal group, and patients with renal osteodystrophy had higher BW (41.4% +/- 9.6) than the premenopausal group by 135% (P < .001) and the postmenopausal group by 43% (P = .02). BMD showed an opposite behavior, with much smaller group differences. Because the majority of BW is in the pore system of cortical bone, this parameter provides a surrogate measure for cortical porosity. CONCLUSION: A new MR imaging-based method for quantifying BW noninvasively has been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709
Cited by
Silk fibroin as biomaterial for bone tissue engineering
Melke, J., Midha, S., Ghosh, S., Ito, K., & Hofmann, S. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.09.005 · Cited by 789
Bone composition: relationship to bone fragility and antiosteoporotic drug effects
Boskey, A. L. (2013) · BoneKEy Reports · doi:10.1038/bonekey.2013.181 · Cited by 424
Methods for Assessing Bone Quality: A Review
Donnelly, E. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1702-0 · Cited by 300
UTE imaging in the musculoskeletal system
Chang, E. Y., Du, J., & Chung, C. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24713 · Cited by 276
The Role of Water Compartments in the Material Properties of Cortical Bone
Granke, M., Does, M. D., & Nyman, J. S. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-9977-5 · Cited by 252
Metadata
- Authors
- Techawiboonwong, A., Song, H. K., Leonard, M. B., & Wehrli, F. W.
- Venue
- Radiology
- Published
- 2008-09
- Volume
- 248
- Issue
- 3
- Pages
- 824-833
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2109392661
- Cited by
- 222
- References
- 1
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2482071995
- The paper
- Techawiboonwong, A., Song, H. K., Leonard, M. B., & Wehrli, F. W. (2008). Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR Imaging. Radiology. https://doi.org/10.1148/radiol.2482071995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.