Uterine Leiomyomas: MR Imaging–guided Focused Ultrasound Surgery—Imaging Predictors of Success
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively assess the magnetic resonance (MR) imaging predictors of success at reducing uterine leiomyoma volume and achieving patient symptom relief 12 months after MR imaging-guided focused ultrasound surgery. MATERIALS AND METHODS: This single-center retrospective analysis of 71 symptomatic fibroids in 66 women was approved by the institutional review board and was HIPAA-compliant. Patients were treated with MR imaging-guided focused ultrasound surgery. The volume of treated fibroid and nonperfused volume (NPV) were calculated with software, while symptom outcome was assessed with a symptom severity score (SSS). Fibroids were classified as hyperintense or hypointense relative to skeletal muscle on pretreatment T2-weighted MR images. RESULTS: Baseline volume of treated fibroids was 255.5 cm(3) +/- 201.7 (standard deviation), and baseline SSS was 61.5 +/- 14.9. Both pretreatment fibroid signal intensity (SI) and posttreatment NPV predicted 12-month volume reduction independently: Fibroids with an NPV of at least 20% or with low SI both showed significantly larger volume reduction (17.0% +/- 13.0 and 17.2% +/- 20.1, respectively) than fibroids with an NPV less than 20% or with high SI (10.7% +/- 18.2 and no significant change, respectively). Patients whose fibroids demonstrated an NPV of at least 20% also experienced a larger decrease in SSS than did patients with fibroids with an NPV less than 20% (50.1% +/- 19.8 vs 32.6% +/- 29.9). CONCLUSION: Fibroids with low SI on pretreatment T2-weighted MR images were more likely to shrink than were ones with high SI. The larger the NPV immediately after treatment, the greater the volume reduction and symptom relief were. These findings may help both in selecting appropriate patients for MR-guided focused ultrasound surgery and in predicting patient outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A precise and fast temperature mapping using water proton chemical shift
Ishihara, Y., Calderon, A., Watanabe, H., Okamoto, K., Suzuki, Y., Kuroda, K., & Suzuki, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340606 · Cited by 1,027 · cited 1×
“Phase-difference fast spoiled gradient-echo MR imaging was used to construct the temperature images (10).”
MethodSpies, J. (2002) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(01)01702-1 · Cited by 647
Clinical outcomes of focused ultrasound surgery for the treatment of uterine fibroids
Stewart, E. A., Rabinovici, J., Tempany, C. M. C., Inbar, Y., Regan, L., Gastout, B., Hesley, G., Kim, H. S., Hengst, S., & Gedroye, W. M. (2006) · Fertility and Sterility · doi:10.1016/j.fertnstert.2005.04.072 · Cited by 480 · cited 1×
“Of the patients included in this study, 13 were from the pivotal trial population (4), 50 were from the continued access study (5), and three were part of a”
BackgroundSelf-citationMRI Guidance of Focused Ultrasound Therapy of Uterine Fibroids: Early Results
Hindley, J. T., Gedroyc, W. M. W., Regan, L., Stewart, E. A., Tempany, C. M., Hynnen, K., MacDannold, N., Inbar, Y., Itzchak, Y., Rabinovici, J., et al. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.6.01831713 · Cited by 441 · cited 3×
“This finding is in line with the results of Hindley et al (3), which were a 13.”
BackgroundResultInfluentialSelf-citationSustained Relief of Leiomyoma Symptoms by Using Focused Ultrasound Surgery
Stewart, E. A., Gostout, B., Rabinovici, J., Kim, H. S., Regan, L., & Tempany, C. M. C. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000275283.39475.f6 · Cited by 332 · cited 1×
“Treatments performed according to initial guidelines led to significant improvement in symptoms despite small volumes of tissue ablated and have been shown to be sustained 12 and 24 months after treatment in many patients (5,7).”
BackgroundSelf-citationSustained Relief of Leiomyoma Symptoms by Using Focused Ultrasound Surgery
Stewart, E. A. (2008) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e318166e9da · Cited by 277
Self-citationFennessy, F. M., Tempany, C. M., McDannold, N. J., So, M. J., Hesley, G., Gostout, B., Kim, H. S., Holland, G. A., Sarti, D. A., Hynynen, K., et al. (2007) · Radiology · doi:10.1148/radiol.2433060267 · Cited by 242
Self-citationMcDannold, N., Tempany, C. M., Fennessy, F. M., So, M. J., Rybicki, F. J., Stewart, E. A., Jolesz, F. A., & Hynynen, K. (2006) · Radiology · doi:10.1148/radiol.2401050717 · Cited by 231 · cited 1×
“During each sonication, the focused ultrasound system automatically started the temperature-sensitive imaging sequence that was used to guide the procedure (8).”
MethodSelf-citationFiscella, K., Eisinger, S. H., Meldrum, S., Feng, C., Fisher, S. G., & Guzick, D. S. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000243776.23391.7b · Cited by 193
Spies, J. B., Allison, S. J., Flick, P. A., McCullough, M. F., Sterbis, K., Cramp, M., Bruno, J. M., & Jha, R. C. (2004) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000136982.42548.5d · Cited by 166
Smart, O. C., Hindley, J. T., Regan, L., & Gedroyc, W. M. W. (2006) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000222381.94325.4f · Cited by 107 · cited 1×
“Somewhat larger changes were reported in another study (16): Fibroid volume decreased by 21% at 6-month and by 37% at 12-month follow-up, while symptom severity was reduced by 45% at 6-month and 48% at 12-month follow-up.”
BackgroundPatient satisfaction and disease specific quality of life after uterine artery embolization
Smith, W. J., Upton, E., Shuster, E. J., Klein, A. J., & Schwartz, M. L. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.02.043 · Cited by 63
Cited by
Izadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
High intensity focused ultrasound: The fundamentals, clinical applications and research trends
Elhelf, I. A. S., Albahar, H., Shah, U., Oto, A., Cressman, E., & Almekkawy, M. (2018) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2018.03.001 · Cited by 264
Clinical and future applications of high intensity focused ultrasound in cancer
Al-Bataineh, O., Jenne, J., & Huber, P. (2012) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2011.08.004 · Cited by 241
MRI-guided focused ultrasound treatments
Hynynen, K. (2010) · Ultrasonics · doi:10.1016/j.ultras.2009.08.015 · Cited by 235
“Symptom relief was shown to be significant in approximately 80% of the patients in the first studies [28], with significantly better results in fibroids that received a larger coagulated tissue volume [33].”
Self-citation
Metadata
- Authors
- Lénárd, Z. M., McDannold, N. J., Fennessy, F. M., Stewart, E. A., Jolesz, F. A., Hynynen, K., & Tempany, C. M. C.
- Venue
- Radiology
- Published
- 2008-10
- Volume
- 249
- Issue
- 1
- Pages
- 187-194
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1969931130
- Cited by
- 173
- References
- 12
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.