Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 231

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Uterine Leiomyomas: MR Imaging–based Thermometry and Thermal Dosimetry during Focused Ultrasound Thermal Ablation

Open access
McDannold, Nathan, Tempany, Clare M., Fennessy, Fiona M., So, Minna J., Rybicki, Frank J., Stewart, Elizabeth A., Jolesz, Ferenc A., Hynynen, Kullervo·2006·Radiology

Abstract

PURPOSE: To retrospectively evaluate magnetic resonance (MR) imaging-based thermometry and thermal dosimetry during focused ultrasound treatments of uterine leiomyomas (ie, fibroids). MATERIALS AND METHODS: All patients gave written informed consent for the focused ultrasound treatments and the current HIPAA-compliant retrospective study, both of which were institutional review board approved. Thermometry performed during the treatments of 64 fibroids in 50 women (mean age, 46.6 years +/- 4.5 [standard deviation]) was used to create thermal dose maps. The areas that reached dose values of 240 and 18 equivalent minutes at 43 degrees C were compared with the nonperfused regions measured on contrast material-enhanced MR images by using the Bland-Altman method. Volume changes in treated fibroids after 6 months were compared with volume changes in nontreated fibroids and with MR-based thermal dose estimates. RESULTS: While the thermal dose estimates were shown to have a clear relationship with resulting nonperfused regions, the nonperfused areas were, on average, larger than the dose estimates (means of 1.9 +/- 0.7 and 1.2 +/- 0.4 times as large for areas that reached 240- and 18-minute threshold dose values, respectively). Good correlation was observed for smaller treatment volumes at the lower dose threshold (mean ratio, 1.0 +/- 0.3), but for larger treatment volumes, the nonperfused region extended to locations within the fibroid that clearly were not heated. Variations in peak temperature increase were as large as a factor of two, both between patients and within individual treatments. On average, the fibroid volume reduction at 6 months increased as the ablated volume estimated by using the thermal dose increased. CONCLUSION: Study results showed good correlation between thermal dose estimates and resulting nonperfused areas for smaller ablated volumes. For larger treatment volumes, nonperfused areas could extend within the fibroid to unheated areas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2401050717

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
McDannold, N., Tempany, C. M., Fennessy, F. M., So, M. J., Rybicki, F. J., Stewart, E. A., Jolesz, F. A., & Hynynen, K.
Venue
Radiology
Published
2006-07
Volume
240
Issue
1
Pages
263-272
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2051214183
Cited by
231
References
1
FWCI
13.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Uterine Leiomyomas: MR Imaging–based Thermometry and Thermal Dosimetry during Focused Ultrasound Thermal Ablation. https://app.cochat.ai/papers/10.1148/radiol.2401050717
The paper
McDannold, N., Tempany, C. M., Fennessy, F. M., So, M. J., Rybicki, F. J., Stewart, E. A., Jolesz, F. A., & Hynynen, K. (2006). Uterine Leiomyomas: MR Imaging–based Thermometry and Thermal Dosimetry during Focused Ultrasound Thermal Ablation. Radiology. https://doi.org/10.1148/radiol.2401050717

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.