Cited by 44Colorectal Cancer Screening and DetectionRadiology practices and educationInnovations in Medical Education

Formative Evaluation of Standardized Training for CT Colonographic Image Interpretation by Novice Readers

Dachman, Abraham H., Kelly, Katherine B., Zintsmaster, Michael P., Rana, Rich, Khankari, Shweta, Novak, Joseph D., Ali, Arif N., Qalbani, Adnan +1 more·2008·Radiology

Abstract

PURPOSE: To introduce an educational intervention-specifically, a specialized training course-and perform a formative evaluation of the effect of the intervention on novice reader interpretation of computed tomography (CT) colonographic data. MATERIALS AND METHODS: The study was institutional review board approved. Ten normal and 50 abnormal cases, those of 60 patients with 93 polyps-61 polyps 6-9 mm in diameter and 32 polyps 10 mm or larger-were selected from a previously published trial. Seven novice readers underwent initial training that consisted of a 1-day course, reading assignments, a self-study computer module (with 61 limited data sets), observation of an expert interpreting three cases, and full interpretation of 10 cases with unblinding after each case. After training, the observers independently interpreted 60 cases by means of primary two-dimensional reading with unblinding after each case. For each case, the reading time and the location and maximal diameter of the polyp(s) were recorded. A t test was used to evaluate the observers' improvements, and empirical receiver operating characteristic (ROC) curves were constructed. RESULTS: By-patient sensitivities and specificities were determined for each observer. The lowest by-patient sensitivity at the 6 mm or larger polyp threshold was 86%, with 90% specificity. Four observers had 100% by-patient sensitivity at the 10 mm or larger polyp threshold, with 82%-97% specificity. For polyps 10 mm or larger, mean sensitivity and specificity were 98% and 92%, respectively. For the last 20 cases, the average interpretation time per case was 25 minutes. The range of areas under the ROC curve across observers was low: 0.86-0.95. CONCLUSION: In the described polyp-enriched cohort, novice CT colonographic data readers achieved high sensitivity and good specificity at formative evaluation of a comprehensive training program. Use of a similar comprehensive training method might reduce interreader variability in interpretation accuracy and be useful for reader certification.

Integrity signals

Registry

Crossref · 10.1148/radiol.2491080059

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Reports indicate enhanced X-ray diagnostic techniques by technicians in medically underserved areas such as South Africa and Australia, as well as specialised diagnostic improvements for CT colonographic data, endometrial tumours and malignant skin tumours.

    “Reports indicate enhanced X-ray diagnostic techniques by technicians in medically underserved areas such as South Africa18 and Australia,19 as well as specialised diagnostic improvements for CT colonographic data,20 endometrial tumours21 and malignant skin tumours.22”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dachman, A. H., Kelly, K. B., Zintsmaster, M. P., Rana, R., Khankari, S., Novak, J. D., Ali, A. N., Qalbani, A., & Fletcher, J. G.
Affiliations
  • University of Chicago (US)
  • Mayo Clinic (US)
Venue
Radiology
Published
2008-10
Volume
249
Issue
1
Pages
167-177
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2044571035
Cited by
44
References
39
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2018: 1 · 2017: 1 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 8
FWCI
4.22
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Oncology › Colorectal Cancer Screening and Detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Innovations in Medical Education
Keywords
CT colonography, polyp detection, radiology education, beginning readers, formative assessment, interobserver variability, colorectal cancer screening
MeSH terms
Colonic Polyps, Education, Medical, Continuing, Humans, Sensitivity and Specificity, Teaching, Colonography, Computed Tomographic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review