CoChat

Imaging Nanoprobe for Prediction of Outcome of Nanoparticle Chemotherapy by Using Mammography

Karathanasis, Efstathios, Suryanarayanan, Sankararaman, Balusu, Sri R., McNeeley, Kathleen, Sechopoulos, Ioannis, Karellas, Andrew, Annapragada, Ananth V., Bellamkonda, Ravi V. · 2009 · Radiology
Cited by 97

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively predict the effectiveness of a clinically used nanochemotherapeutic agent by detecting and measuring the intratumoral uptake of an x-ray contrast agent nanoprobe by using digital mammography. MATERIALS AND METHODS: All animal procedures were approved by the institutional animal care and use committee. A long-circulating 100-nm-scale injectable liposomal probe encapsulating 155 mg/mL iodine was developed. Preliminary studies were performed to identify the agent dose that would result in adequate tumor enhancement without enhancement of the normal vasculature in rats. This dose was used to image a rat breast tumor (n = 14) intermittently for 3 days by using a digital mammography system; subsequently, the animals were treated with liposomal doxorubicin. The predictive capability of the probe was characterized by creating good- and bad-prognosis subgroups, on the basis of tumor enhancement found during imaging, and analyzing the tumor growth after treatment of the animals in these two subgroups. RESULTS: A dose of 455 mg of iodine per kilogram of body weight was found to produce an undetectable signal from the blood while achieving enough intratumoral accumulation of the probe to produce adequate signal for detection. The good- and bad-prognosis subgroups demonstrated differential tumor growth rates (P < .003). An inverse linear relationship between the contrast enhancement rate constant during imaging and the tumor growth rate constant during treatment was found (slope = -0.576, R(2) = 0.838). CONCLUSION: In this animal model, quantitative measurement of vascular permeability enabled prediction of therapeutic responsiveness of tumors to liposomal doxorubicin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2502080801

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 97

Metadata

Authors
Karathanasis, E., Suryanarayanan, S., Balusu, S. R., McNeeley, K., Sechopoulos, I., Karellas, A., Annapragada, A. V., & Bellamkonda, R. V.
Venue
Radiology
Published
2009-02
Volume
250
Issue
2
Pages
398-406
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1983310647
Cited by
97
References
3
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging Nanoprobe for Prediction of Outcome of Nanoparticle Chemotherapy by Using Mammography. https://app.cochat.ai/papers/10.1148/radiol.2502080801
The paper
Karathanasis, E., Suryanarayanan, S., Balusu, S. R., McNeeley, K., Sechopoulos, I., Karellas, A., Annapragada, A. V., & Bellamkonda, R. V. (2009). Imaging Nanoprobe for Prediction of Outcome of Nanoparticle Chemotherapy by Using Mammography. Radiology. https://doi.org/10.1148/radiol.2502080801

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.