Imaging Nanoprobe for Prediction of Outcome of Nanoparticle Chemotherapy by Using Mammography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively predict the effectiveness of a clinically used nanochemotherapeutic agent by detecting and measuring the intratumoral uptake of an x-ray contrast agent nanoprobe by using digital mammography. MATERIALS AND METHODS: All animal procedures were approved by the institutional animal care and use committee. A long-circulating 100-nm-scale injectable liposomal probe encapsulating 155 mg/mL iodine was developed. Preliminary studies were performed to identify the agent dose that would result in adequate tumor enhancement without enhancement of the normal vasculature in rats. This dose was used to image a rat breast tumor (n = 14) intermittently for 3 days by using a digital mammography system; subsequently, the animals were treated with liposomal doxorubicin. The predictive capability of the probe was characterized by creating good- and bad-prognosis subgroups, on the basis of tumor enhancement found during imaging, and analyzing the tumor growth after treatment of the animals in these two subgroups. RESULTS: A dose of 455 mg of iodine per kilogram of body weight was found to produce an undetectable signal from the blood while achieving enough intratumoral accumulation of the probe to produce adequate signal for detection. The good- and bad-prognosis subgroups demonstrated differential tumor growth rates (P < .003). An inverse linear relationship between the contrast enhancement rate constant during imaging and the tumor growth rate constant during treatment was found (slope = -0.576, R(2) = 0.838). CONCLUSION: In this animal model, quantitative measurement of vascular permeability enabled prediction of therapeutic responsiveness of tumors to liposomal doxorubicin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438
Tumor microenvironment abnormalities: Causes, consequences, and strategies to normalize
Fukumura, D., & Jain, R. K. (2007) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21187 · Cited by 584
Cited by
Bertrand, N., Wu, J., Xu, X., Kamaly, N., & Farokhzad, O. C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.009 · Cited by 2,824
Challenges and strategies in anti-cancer nanomedicine development: An industry perspective
Hare, J. I., Lammers, T., Ashford, M. B., Puri, S., Storm, G., & Barry, S. T. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.025 · Cited by 1,214
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Rethinking cancer nanotheranostics
Chen, H., Zhang, W., Zhu, G., Xie, J., & Chen, X. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.24 · Cited by 1,102
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Ernsting, M. J., Murakami, M., Roy, A., & Li, S.-D. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.09.013 · Cited by 1,012
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Shaping Cancer Nanomedicine: The Effect of Particle Shape on The In Vivo Journey of Nanoparticles
Toy, R., Peiris, P. M., Ghaghada, K. B., & Karathanasis, E. (2014) · Nanomedicine · doi:10.2217/nnm.13.191 · Cited by 570
Self-citationNanoparticles in Daily Life: Applications, Toxicity and Regulations
Gupta, R., & Xie, H. (2018) · Journal of Environmental Pathology, Toxicology and Oncology · doi:10.1615/jenvironpatholtoxicoloncol.2018026009 · Cited by 553
Nanotheranostics for personalized medicine
Mura, S., & Couvreur, P. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.06.006 · Cited by 527
PEG-PCL-based nanomedicines: A biodegradable drug delivery system and its application
Grossen, P., Witzigmann, D., Sieber, S., & Huwyler, J. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.028 · Cited by 496
Interactions of nanomaterials and biological systems: Implications to personalized nanomedicine
Zhang, X.-Q., Xu, X., Bertrand, N., Pridgen, E., Swami, A., & Farokhzad, O. C. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.005 · Cited by 487
Lee, H., Shields, A. F., Siegel, B. A., Miller, K. D., Krop, I., Ma, C. X., LoRusso, P. M., Munster, P. N., Campbell, K., Gaddy, D. F., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-3193 · Cited by 393
The effects of particle size, density and shape on margination of nanoparticles in microcirculation
Toy, R., Hayden, E., Shoup, C., Baskaran, H., & Karathanasis, E. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/11/115101 · Cited by 254
Self-citationNew insights and evolving role of pegylated liposomal doxorubicin in cancer therapy
Gabizon, A. A., Patil, Y., & La-Beck, N. M. (2016) · Drug Resistance Updates · doi:10.1016/j.drup.2016.10.003 · Cited by 250
“Karathanasis et al., 2009).”
Inorganic nanoparticle-based contrast agents for molecular imaging
Cho, E. C., Glaus, C., Chen, J., Welch, M. J., & Xia, Y. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.09.004 · Cited by 247
“, liposome, micelles, and polymeric particles) have also been explored as contrast agents for molecular imaging [19,20].”
BackgroundTargeted nanotechnology for cancer imaging
Toy, R., Bauer, L., Hoimes, C., Ghaghada, K. B., & Karathanasis, E. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.08.002 · Cited by 192
“For example, liposomal CT agents have been used as prognosticating agents for monitoring the effects of PEGylated liposomal doxorubicin (PLD) in breast cancer [29].”
Self-citationPeiris, P. M., Bauer, L., Toy, R., Tran, E., Pansky, J., Doolittle, E., Schmidt, E., Hayden, E., Mayer, A., Keri, R. A., et al. (2012) · ACS Nano · doi:10.1021/nn300652p · Cited by 177
Self-citationEck, W., Nicholson, A. I., Zentgraf, H., Semmler, W., & Bartling, S. (2010) · Nano Letters · doi:10.1021/nl101019s · Cited by 163
Prediction of anti-cancer nanotherapy efficacy by imaging
Miller, M. A., Arlauckas, S., & Weissleder, R. (2017) · Nanotheranostics · doi:10.7150/ntno.20564 · Cited by 74
Cerebral Vascular Leak in a Mouse Model of Amyloid Neuropathology
Tanifum, E. A., Starosolski, Z. A., Fowler, S. W., Jankowsky, J. L., & Annapragada, A. V. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.125 · Cited by 28
Self-citation
Metadata
- Authors
- Karathanasis, E., Suryanarayanan, S., Balusu, S. R., McNeeley, K., Sechopoulos, I., Karellas, A., Annapragada, A. V., & Bellamkonda, R. V.
- Venue
- Radiology
- Published
- 2009-02
- Volume
- 250
- Issue
- 2
- Pages
- 398-406
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1983310647
- Cited by
- 97
- References
- 3
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.