Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen

Braithwaite, Adam C., Dale, Brian M., Boll, Daniel T., Merkle, Elmar M. · 2009 · Radiology

Abstract

PURPOSE: To test the hypothesis that there is no significant variability in apparent diffusion coefficients (ADCs) at assessment of the short- and midterm reproducibility of ADC measurements in a healthy population. MATERIALS AND METHODS: Twenty healthy male volunteers were enrolled in this prospective institutional review board-approved study after they provided written informed consent. A 3.0-T magnetic resonance (MR) system was used to perform five axial diffusion-weighted (DW) abdominal acquisitions (session 1). A mean of 147 days +/- 20 (standard deviation) later, 16 of the 20 volunteers were imaged again with use of the same protocol and MR system (session 2). The mean ADCs for three regions of interest (ROIs) in five anatomic locations (right hepatic lobe, spleen, and head, body, and tail of pancreas) were calculated. The coefficient of variation (CV, equal to standard deviation divided by mean) was calculated for each subject, session, and anatomic location. The ADC and CV data were then analyzed by using repeated-measures analysis of variance. RESULTS: There were significant differences (P < .001) in mean ADCs among the five anatomic locations. There were no significant differences in ADCs among the various repeated sequence acquisitions or the three ROIs. There were no significant differences in ADCs between imaging sessions 1 and 2. ADCs were fairly stable over the midterm within a given individual. Finally, there were no significant differences in resulting CVs between the imaging sessions or anatomic locations. The mean CV for ADC measurement reproducibility was 14% (95% confidence interval: 13%, 15%). CONCLUSION: The mean CV for short- and midterm ADC reproducibility was 14% at abdominal DW imaging. Treatment effects of less than approximately 27% (change in ADC divided by pretreatment ADC) will not be clinically detectable with confidence with one acquisition in a single individual.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2502080849

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 195

Metadata

Authors
Braithwaite, A. C., Dale, B. M., Boll, D. T., & Merkle, E. M.
Venue
Radiology
Published
2009-02
Volume
250
Issue
2
Pages
459-465
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2089242875
Cited by
195
References
1
FWCI
7.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen. https://app.cochat.ai/papers/10.1148/radiol.2502080849
The paper
Braithwaite, A. C., Dale, B. M., Boll, D. T., & Merkle, E. M. (2009). Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen. Radiology. https://doi.org/10.1148/radiol.2502080849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.