PURPOSE: To test the hypothesis that there is no significant variability in apparent diffusion coefficients (ADCs) at assessment of the short- and midterm reproducibility of ADC measurements in a healthy population. MATERIALS AND METHODS: Twenty healthy male volunteers were enrolled in this prospective institutional review board-approved study after they provided written informed consent. A 3.0-T magnetic resonance (MR) system was used to perform five axial diffusion-weighted (DW) abdominal acquisitions (session 1). A mean of 147 days +/- 20 (standard deviation) later, 16 of the 20 volunteers were imaged again with use of the same protocol and MR system (session 2). The mean ADCs for three regions of interest (ROIs) in five anatomic locations (right hepatic lobe, spleen, and head, body, and tail of pancreas) were calculated. The coefficient of variation (CV, equal to standard deviation divided by mean) was calculated for each subject, session, and anatomic location. The ADC and CV data were then analyzed by using repeated-measures analysis of variance. RESULTS: There were significant differences (P < .001) in mean ADCs among the five anatomic locations. There were no significant differences in ADCs among the various repeated sequence acquisitions or the three ROIs. There were no significant differences in ADCs between imaging sessions 1 and 2. ADCs were fairly stable over the midterm within a given individual. Finally, there were no significant differences in resulting CVs between the imaging sessions or anatomic locations. The mean CV for ADC measurement reproducibility was 14% (95% confidence interval: 13%, 15%). CONCLUSION: The mean CV for short- and midterm ADC reproducibility was 14% at abdominal DW imaging. Treatment effects of less than approximately 27% (change in ADC divided by pretreatment ADC) will not be clinically detectable with confidence with one acquisition in a single individual.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993 · cited 1×
“Oncologic applications have been of particular interest because lipophilic cell membranes in hypercellular tumor tissue serve as barriers to free diffusion in the intracellular and extracellular spaces (2,3).”
BackgroundMoffat, B. A., Chenevert, T. L., Lawrence, T. S., Meyer, C. R., Johnson, T. D., Dong, Q., Tsien, C., Mukherji, S., Quint, D. J., Gebarski, S. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501532102 · Cited by 643 · cited 1×
“Studies have shown that low baseline pretreatment ADCs in cerebral gliomas, colorectal hepatic metastases, and primary rectal carcinomas (11,19,20) suggest a better response to chemotherapy and radiation treatment than do high baseline ADCs in these lesions.”
BackgroundParikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Bruegel, M., Holzapfel, K., Gaa, J., Woertler, K., Waldt, S., Kiefer, B., Stemmer, A., Ganter, C., & Rummeny, E. J. (2007) · European Radiology · doi:10.1007/s00330-007-0785-9 · Cited by 428 · cited 4×
“There were similar discrepancies for the spleen: Bruegel et al reported a mean ADC of 0.82 10 3 mm2/sec in 96 patients, which again is approximately 50% lower than the values that we measured (5).”
BackgroundInfluentialKoh, D.-M., Scurr, E., Collins, D., Kanber, B., Norman, A., Leach, M. O., & Husband, J. E. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0601 · Cited by 344 · cited 3×
“Koh et al (11) expanded on this theory by using ADC measurements to monitor the treatment effects of chemotherapeutic agents for colorectal cancer.”
BackgroundADC Measurement of Abdominal Organs and Lesions Using Parallel Imaging Technique
Yoshikawa, T., Kawamitsu, H., Mitchell, D. G., Ohno, Y., Ku, Y., Seo, Y., Fujii, M., & Sugimura, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0778 · Cited by 300
Mardor, Y., Pfeffer, R., Spiegelmann, R., Roth, Y., Maier, S. E., Nissim, O., Berger, R., Glicksman, A., Baram, J., Orenstein, A., et al. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.05.069 · Cited by 287 · cited 2×
“Other studies have shown that an early posttreatment increase in ADCs in cerebral gliomas and breast carcinoma that precedes any reduction in tumor size is predictive of a better treatment outcome (20,21).”
BackgroundResultExtracranial applications of diffusion-weighted magnetic resonance imaging
Thoeny, H. C., & De Keyzer, F. (2007) · European Radiology · doi:10.1007/s00330-006-0547-0 · Cited by 269 · cited 1×
“With the development of faster techniques and sequences, the use of diffusion-weighted (DW) imaging has expanded beyond intracranial applications to abdominal applications (1).”
MethodFujii, S., Matsusue, E., Kanasaki, Y., Kanamori, Y., Nakanishi, J., Sugihara, S., Kigawa, J., Terakawa, N., & Ogawa, T. (2008) · European Radiology · doi:10.1007/s00330-007-0732-9 · Cited by 220
Practical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
KOH, D.-M., TAKAHARA, T., IMAI, Y., & COLLINS, D. J. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.211 · Cited by 211 · cited 2×
“Other groups, such as Koh et al, share our opinion that a free-breathing approach “allows good use of DWI images for both qualitative and quantitative analysis” (2).”
BackgroundMethod
Cited by
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Shukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Koh, D.-M., Scurr, E., Collins, D., Kanber, B., Norman, A., Leach, M. O., & Husband, J. E. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0601 · Cited by 344
Kyriazi, S., Collins, D. J., Messiou, C., Pennert, K., Davidson, R. L., Giles, S. L., Kaye, S. B., & deSouza, N. M. (2011) · Radiology · doi:10.1148/radiol.11110577 · Cited by 221
Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S. (2020) · Investigative Radiology · doi:10.1097/rli.0000000000000666 · Cited by 183
Zhang, J. L., Sigmund, E. E., Chandarana, H., Rusinek, H., Chen, Q., Vivier, P.-H., Taouli, B., & Lee, V. S. (2010) · Radiology · doi:10.1148/radiol.09090891 · Cited by 179
Diffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175
“For normal tissues in the abdomen, a short-term and longterm repeatability study on one 3T scanner revealed a 14% coefficient of variation (CV 5 SD/mean).(29) These results were similar to another abdominal study that also compared various acquisition techniques.”
Dale, B. M., Braithwaite, A. C., Boll, D. T., & Merkle, E. M. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181c8ceac · Cited by 161
“These 16 subjects also participated in a previously reported study on abdominal DWI reproducibility.(19) A single dedicated body matrix array coil positioned over the abdomen combined with the spine array coils were used for signal reception.”
BackgroundSelf-citationDALSA: domain adaptation for supervised learning from sparsely annotated MR images
Goetz, M., Weber, C., Binczyk, F., Polanska, J., Tarnawski, R., Bobek-Billewicz, B., Koethe, U., Kleesiek, J., Stieltjes, B., & Maier-Hein, K. H. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2463078 · Cited by 98
“Thus, both gray scale images and MRI-derived semi-quantitative values (like apparent diffusion coefficient ADC, or fractional anisotropy FA) exhibit a substantial variability; a variation of 15% is not extraordinary (e.g. [17] for the ADC).”
Background
Metadata
- Authors
- Braithwaite, A. C., Dale, B. M., Boll, D. T., & Merkle, E. M.
- Venue
- Radiology
- Published
- 2009-02
- Volume
- 250
- Issue
- 2
- Pages
- 459-465
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2089242875
- Cited by
- 195
- References
- 17
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.