The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection—Initial Clinical Experience
Abstract
PURPOSE: To intraindividually compare a low tube voltage (80 kVp), high tube current computed tomographic (CT) technique with a standard CT protocol (140 kVp) in terms of image quality, radiation dose, and detection of malignant hypervascular liver tumors during the late hepatic arterial phase. MATERIALS AND METHODS: This prospective single-center HIPAA-compliant study had institutional review board approval, and written informed consent was obtained. Forty-eight patients (31 men, 17 women; age range, 35-77 years) with 60 malignant hypervascular liver tumors (mean diameter, 20.1 mm +/- 16.4 [standard deviation]) were enrolled. Pathologic proof of focal lesions was obtained with histopathologic analysis for 33 nodules and imaging follow-up after a minimum of 12 months for 27 nodules. Patients underwent dual-energy 64-section multi-detector row CT. By using vendor-specific software, two imaging protocols-140 kVp and 385 mA (protocol A) and 80 kVp and 675 mA (protocol B)-were compared during the late hepatic arterial phase of contrast enhancement. Paired t tests were used to compare tumor-to-liver contrast-to-noise ratio (CNR) for each lesion, mean image noise, and effective dose between the two data sets. Three readers qualitatively assessed the two data sets in a blinded and independent fashion. Lesion detection and characterization and reader confidence were recorded, as well as readers' subjective evaluations of image quality. Wilcoxon-Mann-Whitney statistical analysis was performed on this assessment. RESULTS: Image noise increased from 5.7 to 11.4 HU as the tube voltage decreased from 140 to 80 kVp (P < .0001), resulting in a significantly lower image quality score (4.0 vs 3.0, respectively) with protocol B according to all readers (P < .001). At the same time, protocol B yielded significantly higher CNR (8.2 vs 6.4) and lesion conspicuity scores (4.6 vs 4.1) than protocol A, along with a lower effective dose (5.1 vs 17.5 mSv) (P < .001 for all). CONCLUSION: By substantially increasing the tumor-to-liver CNR, a low tube voltage, high tube current CT technique improves the conspicuity of malignant hypervascular liver tumors during the late hepatic arterial phase while significantly reducing patient radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791
Cited by
Coursey, C. A., Nelson, R. C., Boll, D. T., Paulson, E. K., Ho, L. M., Neville, A. M., Marin, D., Gupta, R. T., & Schindera, S. T. (2010) · RadioGraphics · doi:10.1148/rg.304095175 · Cited by 375
Self-citationState of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Self-citationDual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Metadata
- Authors
- Marin, D., Nelson, R. C., Samei, E., Paulson, E. K., Ho, L. M., Boll, D. T., DeLong, D. M., Yoshizumi, T. T., & Schindera, S. T.
- Venue
- Radiology
- Published
- 2009-06
- Volume
- 251
- Issue
- 3
- Pages
- 771-779
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2158047352
- Cited by
- 224
- References
- 3
- FWCI
- 14.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection—Initial Clinical Experience. https://app.cochat.ai/papers/10.1148/radiol.2513081330
- The paper
- Marin, D., Nelson, R. C., Samei, E., Paulson, E. K., Ho, L. M., Boll, D. T., DeLong, D. M., Yoshizumi, T. T., & Schindera, S. T. (2009). Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection—Initial Clinical Experience. Radiology. https://doi.org/10.1148/radiol.2513081330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.