CoChat

Elbow Nerves: MR Findings in 60 Asymptomatic Subjects—Normal Anatomy, Variants, and Pitfalls

Husarik, Daniela B., Saupe, Nadja, Pfirrmann, Christian W. A., Jost, Bernhard, Hodler, Juerg, Zanetti, Marco · 2009 · Radiology
Cited by 213

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively evaluate the signal intensity (SI), course, and diameter of elbow nerves and to identify anatomic variants that are potentially associated with nerve compression syndromes on magnetic resonance (MR) images of asymptomatic elbows. MATERIALS AND METHODS: This study was approved by the institutional review board. Informed consent was obtained from each volunteer. Sixty subjects with asymptomatic elbows (age range, 22.4-51.7 years; median age, 32.8 years) underwent MR imaging. Increased SI compared with surrounding muscles on fluid-sensitive MR images, anatomic course, anatomic nerve and muscle variants potentially associated with nerve compression syndromes, and qualitative changes in nerve diameters were evaluated. Quantitative data on the shortest and longest nerve diameters were obtained. RESULTS: Increased SI on fluid-sensitive MR images was seen in the ulnar nerve in 60% (36 of 60) of subjects but was never observed in the median and radial nerves. An atypical intermuscular course of the median nerve between the brachialis and pronator muscles was detected in 17% (10 of 60) of subjects. Ulnar nerve subluxation at the level of the cubital tunnel was seen in 2% (one of 60) of subjects; an anconeus epitrochlearis muscle, in 23% (14 of 60); and a hypertrophic leash of Henry, in 15% (nine of 60). Median nerve dimensions were 2.4 x 4.0 mm (range, 1.0-4.0 x 3.0-7.0 mm) for the ulnar nerve, 1.0 x 1.9 mm (range, 0.8-2.0 x 0.9-5.0 mm) for the radial nerve, and 3.0 x 5.4 mm (range, 1.0-5.0 x 3.0-9.0 mm) for the median nerve. CONCLUSION: Increased SI of the ulnar nerve on fluid-sensitive images (60%), an atypical intermuscular course of the median nerve (17%), and an anconeus epitrochlearis muscle (23%) are common MR findings in asymptomatic elbows.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2521081614

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Husarik, D. B., Saupe, N., Pfirrmann, C. W. A., Jost, B., Hodler, J., & Zanetti, M.
Venue
Radiology
Published
2009-07
Volume
252
Issue
1
Pages
148-156
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2164293615
Cited by
213
References
6
FWCI
7.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.