Microchannel neural interface manufacture by stacking silicone and metal foil laminae
Open accessAbstract
OBJECTIVE: Microchannel neural interfaces (MNIs) overcome problems with recording from peripheral nerves by amplifying signals independent of node of Ranvier position. Selective recording and stimulation using an MNI requires good insulation between microchannels and a high electrode density. We propose that stacking microchannel laminae will improve selectivity over single layer MNI designs due to the increase in electrode number and an improvement in microchannel sealing. APPROACH: This paper describes a manufacturing method for creating MNIs which overcomes limitations on electrode connectivity and microchannel sealing. Laser cut silicone-metal foil laminae were stacked using plasma bonding to create an array of microchannels containing tripolar electrodes. Electrodes were DC etched and electrode impedance and cyclic voltammetry were tested. MAIN RESULTS: MNIs with 100 μm and 200 μm diameter microchannels were manufactured. High electrode density MNIs are achievable with electrodes present in every microchannel. Electrode impedances of 27.2 ± 19.8 kΩ at 1 kHz were achieved. Following two months of implantation in Lewis rat sciatic nerve, micro-fascicles were observed regenerating through the MNI microchannels. SIGNIFICANCE: Selective MNIs with the peripheral nervous system may allow upper limb amputees to control prostheses intuitively.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Originally made from polyimide, more recent microchannel designs are built from stretchable and softer materials such as PDMS.
“While originally made from polyimide (FitzGerald et al., 2012), more recent microchannel designs are built from stretchable and softer materials such as PDMS (Musick et al., 2015; Lancashire et al., 2016).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Lancashire et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I., McCluskey, D. K., Tan, C., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,507 · see citing works
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · see citing works
Topography, Cell Response, and Nerve Regeneration
Hoffman–Kim, D., Mitchel, J. A., & Bellamkonda, R. V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105351 · Cited by 528 · see citing works
Elbow Nerves: MR Findings in 60 Asymptomatic Subjects—Normal Anatomy, Variants, and Pitfalls
Husarik, D. B., Saupe, N., Pfirrmann, C. W. A., et al. (2009) · Radiology · doi:10.1148/radiol.2521081614 · Cited by 212 · see citing works
Schüettler, M., Stieß, S., King, B. V., & Suaning, G. J. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/013 · Cited by 163 · see citing works
Scipio, F. D., Raimondo, S., Tos, P., et al. (2008) · Microscopy Research and Technique · doi:10.1002/jemt.20577 · Cited by 150 · see citing works
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123 · see citing works
Self-citationLaser patterning of platinum electrodes for safe neurostimulation
Green, R. A., Matteucci, P. B., Dodds, C. W. D., Palmer, J., Dueck, W. F., Hassarati, R. T., Byrnes-Preston, P., Lovell, N. H., & Suaning, G. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056017 · Cited by 77 · see citing works
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · see citing works
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · see citing works
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Miller, K., Wittek, A., Joldes, G., et al. (2011) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/978-3-642-13890-4 · Cited by 72 · see citing works
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · see citing works
Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67 · see citing works
"Microflex" - A New Assembling Technique for Interconnects
Stieglitz, T., Beutel, H., & Meyer, J.-U. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/r7bv-511b-21rj-r2fa · Cited by 67 · see citing works
Polyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56 · see citing works
Meredith, D. O., Eschbach, L., Wood, M. A., et al. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30457 · Cited by 49 · see citing works
"Microflex" - A New Assembling Technique for Interconnects
Stieglitz, T. C., Beutel, H., & Meyer, J.-U. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1177/104538900772664585 · Cited by 38 · see citing works
Suaning, G. J., Schüettler, M., Ordonez, J. S., & Lovell, N. H. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369597 · Cited by 34 · see citing works
Stretchable tracks for laser-machined neural electrode arrays
Schüettler, M., Pfau, D., Ordonez, J. S., et al. (2009) · doi:10.1109/iembs.2009.5333224 · Cited by 27 · see citing works
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · see citing works
Interconnection technologies for laser-patterned electrode arrays
Schüettler, M., Henle, C., Ordonez, J. S., Meier, W. P., Guenther, T., & Stieglitz, T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649887 · Cited by 25 · see citing works
A microchannel neural interface with embedded microwires targeting the peripheral nervous system
Kim, B., Reyes, A., Garza, B., & Choi, Y. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2340-3 · Cited by 12 · see citing works
Dodds, C. W. D., Schüettler, M., Guenther, T., Lovell, N. H., & Suaning, G. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090141 · Cited by 12 · see citing works
Recording with microchannel electrodes in a noisy environment
FitzGerald, J. J., Lacour, S. P., & Fawcett, J. W. (2008) · doi:10.1109/iembs.2008.4649084 · Cited by 10 · see citing works
Laser-fabrication of peripheral nerve cuff electrodes with integrated microfluidic channels
Schüettler, M., Schroeer, S., Ordonez, J. S., & Stieglitz, T. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910533 · Cited by 8 · see citing works
Evaluation of negative photo-patternable PDMS for the encapsulation of neural electrodes
Delivopoulos, E., Minev, I. R., & Lacour, S. P. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910593 · Cited by 6 · see citing works
Integration of Microfluidic Channels into Laser-Fabricated Neural Electrode Arrays
Fiedler, E., Schüettler, M., Henle, C., et al. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_583 · Cited by 4 · see citing works
Spiral peripheral nerve interface; updated fabrication process of the regenerative implant
Barrett, R., Benmerah, S., Frommhold, A., & Tarte, E. J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609614 · Cited by 3 · see citing works
NOVEL PROCESSING ROUTES FOR NEURAL INTERFACES
Barrett, R. C. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham) · doi:10.13140/2.1.1683.2647 · Cited by 2 · see citing works
An interconnection method for ultra-compliant electrodes.
Vanhoestenberghe, A., Musick, K. M., Lacour, S. P., et al. (2012) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 2 · see citing works
Self-citationGiagka, V., Vanhoestenberghe, A., Donaldson, N., et al. (2014) · Electronics System-Integration Technology Conference (ESTC) · doi:10.1109/estc.2014.6962780 · Cited by 2 · see citing works
Self-citationNano-Electro-Mechanical Systems: Processes and Devices
Kelkar, A. D., Herr, D. J. C., & Ryan, J. G. (2014) · Nanoscience and Nanoengineering · doi:10.1201/b16957-6 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Starobin J M, Varadarajan V and Aravamudhan S 2011 High- density peripheral nerve resonant stimulation system Proc. BMES Biomedical Engineering Society Annual Meeting (Hartford, Conneticut, USA)
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“…activation phenotype (M1 macrophages) to an anti-inflammatory and tissue generation Frontiers in Bioengineering and Biotechnology | www.frontiersin.org 4 April 2021 | Volume 9 | Article 622524 phenotype (M2 macrophages) (Mantovani et al., 2004; Lawrence and Natoli, 2011; Sridharan et al., 2015).”
BackgroundA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Selective Neuromodulation of the Vagus Nerve
Fitchett, A., Mastitskaya, S., & Aristovich, K. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.685872 · Cited by 94 · see citing works
A Multichannel High-Frequency Power-Isolated Neural Stimulator With Crosstalk Reduction
Jiang, D., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2832541 · Cited by 36 · see citing works
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15 · see citing works
Self-citationAn Active Microchannel Neural Interface with Artifact Reduction
Habibollahi, M., Hanzaee, F. F., Jiang, D., Lancashire, H., & Demosthenous, A. (2021) · 2021 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas51556.2021.9401318 · Cited by 5 · see citing works
Self-citation
- Authors
- Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W.
- Affiliations
- University College London (GB)
- Corresponding author
- Lancashire, Henry T
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-03-22
- Volume
- 13
- Issue
- 3
- Pages
- 034001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2332787502
- Cited by
- 13
- References
- 34
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2021: 4 · 2019: 2 · 2018: 3
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/G036675/1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- peripheral nerve recording, plasma bonding, electrode impedance, sciatic nerve, nerve regeneration, prosthetic control, upper limb amputation
- MeSH terms
- Animals, Electrodes, Electrodes, Implanted, Interferometry, Male, Metals, Neurons, Peripheral Nerves, Prosthesis Design, Rats, Inbred Lew, Silicones, Electric Impedance, Equipment Failure Analysis, Rats, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review