Use of a Computer-aided Detection System to Detect Missed Lung Cancer at Chest Radiography
The DOI matches its Crossref record.
Abstract
PURPOSE: To study the ability of a computer-aided detection (CAD) system to detect lung cancer overlooked at initial interpretation by the radiologist. MATERIALS AND METHODS: Institutional review board approval was given for this study. Patient consent was not required; a HIPAA waiver was granted because of the retrospective nature of the data collection. In patients with lung cancer diagnosed from 1995 to 2006 at two institutions, each chest radiograph obtained prior to tumor discovery was evaluated by two radiologists for an overlooked lesion. The size and location of the nodules were documented and graded for subtlety (grades 1-4, 1 = very subtle). Each radiograph with a missed lesion was analyzed by a commercial CAD system, as was the follow-up image at diagnosis. An age- and sex-matched control group was used to assess CAD false-positive rates. RESULTS: Missed lung cancer was found in 89 patients (age range, 51-86 years; mean age, 65 years; 80 men, nine women) on 114 radiographs. Lesion size ranged from 0.4 to 5.5 cm (mean, 1.8 cm). Lesions were most commonly peripheral (n = 63, 71%) and in upper lobes (n = 67, 75%). Lesion subtlety score was 1, 2, 3, or 4 on 43, 49, 17, and five radiographs, respectively. CAD identified 53 (47%) and 46 (52%) undetected lesions on a per-image and per-patient basis, respectively. The average size of lesions detected with CAD was 1.73 cm compared with 1.85 cm for lesions that were undetected (P = .47). A significant difference (P = .017) was found in the average subtlety score between detected lesions (score, 2.06) and undetected lesions (score, 1.68). An average of 3.9 false-positive results occurred per radiograph; an average of 2.4 false-positive results occurred per radiograph for the control group. CONCLUSION: CAD has the potential to detect approximately half of the lesions overlooked by human readers at chest radiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sim, Y., Chung, M. J., Kotter, E., Yune, S., Kim, M., Do, S., Han, K., Kim, H., Yang, S., Lee, D.-J., et al. (2020) · Radiology · doi:10.1148/radiol.2019182465 · Cited by 248
Nam, J. G., Kim, M., Park, J., Hwang, E. J., Lee, J. H., Hong, J. H., Goo, J. M., & Park, C. M. (2021) · European Respiratory Journal · doi:10.1183/13993003.03061-2020 · Cited by 103
Lee, K. H., Goo, J. M., Park, C. M., Lee, H. J., & Jin, K. N. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.5.564 · Cited by 37
Metadata
- Authors
- White, C. S., Flukinger, T., Jeudy, J., & Chen, J. J.
- Venue
- Radiology
- Published
- 2009-07
- Volume
- 252
- Issue
- 1
- Pages
- 273-281
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2116058894
- Cited by
- 79
- References
- 0
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of a Computer-aided Detection System to Detect Missed Lung Cancer at Chest Radiography. https://app.cochat.ai/papers/10.1148/radiol.2522081319
- The paper
- White, C. S., Flukinger, T., Jeudy, J., & Chen, J. J. (2009). Use of a Computer-aided Detection System to Detect Missed Lung Cancer at Chest Radiography. Radiology. https://doi.org/10.1148/radiol.2522081319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.