The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Variability in Interpretive Performance at Screening Mammography and Radiologists’ Characteristics Associated with Accuracy
Open accessAbstract
PURPOSE: To identify radiologists' characteristics associated with interpretive performance in screening mammography. MATERIALS AND METHODS: The study was approved by institutional review boards of University of Washington (Seattle, Wash) and institutions at seven Breast Cancer Surveillance Consortium sites, informed consent was obtained, and procedures were HIPAA compliant. Radiologists who interpreted mammograms in seven U.S. regions completed a self-administered mailed survey; information on demographics, practice type, and experience in and perceptions of general radiology and breast imaging was collected. Survey data were linked to data on screening mammograms the radiologists interpreted between January 1, 1998, and December 31, 2005, and included patient risk factors, Breast Imaging Reporting and Data System assessment, and follow-up breast cancer data. The survey was returned by 71% (257 of 364) of radiologists; in 56% (205 of 364) of the eligible radiologists, complete data on screening mammograms during the study period were provided; these data were used in the final analysis. An evaluation of whether the radiologists' characteristics were associated with recall rate, false-positive rate, sensitivity, or positive predictive value of recall (PPV(1)) of the screening examinations was performed with logistic regression models that were adjusted for patients' characteristics and radiologist-specific random effects. RESULTS: Study radiologists interpreted 1 036 155 screening mammograms; 4961 breast cancers were detected. Median percentages and interquartile ranges, respectively, were as follows: recall rate, 9.3% and 6.3%-13.2%; false-positive rate, 8.9% and 5.9%-12.8%; sensitivity, 83.8% and 74.5%-92.3%; and PPV(1), 4.0% and 2.6%-5.9%. Wide variability in sensitivity was noted, even among radiologists with similar false-positive rates. In adjusted regression models, female radiologists or fellowship-trained radiologists had significantly higher recall and false-positive rates (P < .05, all). Fellowship training in breast imaging was the only characteristic significantly associated with improved sensitivity (odds ratio, 2.32; 95% confidence interval: 1.42, 3.80; P < .001) and the overall accuracy parameter (odds ratio, 1.61; 95% confidence interval: 1.05, 2.45; P = .028). CONCLUSION: Fellowship training in breast imaging may lead to improved cancer detection, but it is associated with higher false-positive rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Response rates to mail surveys published in medical journals
Asch, D. A., Jedrziewski, M. K., & Christakis, N. A. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00126-1 · Cited by 2,110
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Carney, P. A., Miglioretti, D. L., Yankaskas, B. C., Kerlikowske, K., Rosenberg, R., Rutter, C. M., Geller, B. M., Abraham, L. A., Taplin, S. H., Dignan, M., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-3-200302040-00008 · Cited by 1,142
Self-citationBreast Cancer Screening: A Summary of the Evidence for the U.S. Preventive Services Task Force
Humphrey, L. L., Helfand, M., Chan, B. K. S., & Woolf, S. H. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_1-200209030-00012 · Cited by 1,137
Variability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Self-citationDetection of Ductal Carcinoma In Situ in Women Undergoing Screening Mammography
Ernster, V. L. (2002) · CancerSpectrum Knowledge Environment · doi:10.1093/jnci/94.20.1546 · Cited by 582
Screening for Breast Cancer: Recommendations and Rationale
U.S. Preventive Services Task Force* (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_1-200209030-00011 · Cited by 456
Beam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
Performance Benchmarks for Screening Mammography
Rosenberg, R. D., Yankaskas, B. C., Abraham, L. A., Sickles, E. A., Lehman, C. D., Geller, B. M., Carney, P. A., Kerlikowske, K., Buist, D. S. M., Weaver, D. L., et al. (2006) · Radiology · doi:10.1148/radiol.2411051504 · Cited by 336
Self-citation
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
Deep Convolutional Neural Networks for breast cancer screening
Chougrad, H., Zouaki, H., & Alheyane, O. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.01.011 · Cited by 470
Hubbard, R. A., Kerlikowske, K., Flowers, C. I., Yankaskas, B. C., Zhu, W., & Miglioretti, D. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00004 · Cited by 414
Self-citationMurtaza, G., Shuib, L., Abdul Wahab, A. W., Mujtaba, G., Mujtaba, G., Nweke, H. F., Al-garadi, M. A., Zulfiqar, F., Raza, G., & Azmi, N. A. (2020) · Artificial Intelligence Review · doi:10.1007/s10462-019-09716-5 · Cited by 342
Metadata
- Authors
- Elmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., Sickles, E. A., & Buist, D. S. M.
- Venue
- Radiology
- Published
- 2009-12
- Volume
- 253
- Issue
- 3
- Pages
- 641-651
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2148516878
- Cited by
- 263
- References
- 23
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability in Interpretive Performance at Screening Mammography and Radiologists’ Characteristics Associated with Accuracy. https://app.cochat.ai/papers/10.1148/radiol.2533082308
- The paper
- Elmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., Sickles, E. A., & Buist, D. S. M. (2009). Variability in Interpretive Performance at Screening Mammography and Radiologists’ Characteristics Associated with Accuracy. Radiology. https://doi.org/10.1148/radiol.2533082308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.