The DOI matches its Crossref record.
Variability in the Interpretation of Screening Mammograms by US Radiologists: Findings From a National Sample
Abstract
OBJECTIVE: To evaluate the effectiveness of screening mammography by estimating the variability in radiologists' ability to detect breast cancer within the US population of radiologists at mammography centers accredited by the American College of Radiology. METHODS: A two-way sample survey design was used as follows. Fifty mammography centers having an American College of Radiology-accredited unit were randomly sampled from across the United States. One hundred eight radiologists from these centers gave blinded interpretation to the same set of 79 randomly selected screening mammograms. The mammograms were from women who had been screened at a large screening center. Before their sampling, these women had been stratified by their breast disease status, established either by biopsy or by 2-year follow-up. Rates of biopsy recommendations were summarized by the mean, median, minimum, maximum, and range of sensitivity and specificity. Overall cancer detection ability was summarized by similar statistics for receiver operating characteristic curve areas. Ninety-five percent lower confidence bounds on the ranges in accuracy measures were established by boo-strapping. RESULTS: There is a range of at least 40% among US radiologists in their screening sensitivity. There is a range of at least 45% in the rates at which women without breast cancer are recommended for biopsy. As indicated by receiver operating characteristic curve areas, the ability of radiologists to detect cancer mammograms varies by as much as 11%. CONCLUSIONS: Our findings indicate that there is wide variability in the accuracy of mammogram interpretation in the population of US radiologists. Current accreditation programs that certify the technical quality of radiographic equipment and images but not the accuracy of the interpretation given to mammograms may not be sufficient to help mammography fully realize its potential to reduce breast cancer mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.6.1741769 · Cited by 1,273
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Overconfidence as a Cause of Diagnostic Error in Medicine
Berner, E. S., & Graber, M. L. (2008) · The American Journal of Medicine · doi:10.1016/j.amjmed.2008.01.001 · Cited by 1,034
Burke, W. (1997) · JAMA · doi:10.1001/jama.277.12.997 · Cited by 955
Metadata
- Authors
- Beam, C. A.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1996-01-22
- Volume
- 156
- Issue
- 2
- Pages
- 209
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4236100285
- Cited by
- 337
- References
- 0
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability in the Interpretation of Screening Mammograms by US Radiologists: Findings From a National Sample. https://app.cochat.ai/papers/10.1001/archinte.1996.00440020119016
- The paper
- Beam, C. A. (1996). Variability in the Interpretation of Screening Mammograms by US Radiologists: Findings From a National Sample. Archives of Internal Medicine. https://doi.org/10.1001/archinte.1996.00440020119016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.