CoChat

Nuclear magnetic resonance characteristics of fresh and fixed tissue: the effect of elapsed time.

Thickman, D I, Kundel, H L, Wolf, G · 1983 · Radiology
Cited by 103

The DOI matches its Crossref record.

Abstract

The nuclear magnetic resonance relaxation times T1 and T2 of liver and spleen from freshly euthanized rats were measured over 48 hours for samples treated with normal saline, fixed with 70% ethanol, neutral buffered formalin, or 10% formalin, or left untreated. The initial values of T1 and T2 for both tissues agreed with previous determinations. For untreated tissues of both liver and spleen, T1 was stable for 6 hours and T2 was stable for 48 hours. For fixed tissues, T1 was stable for 0.5 hours, but T2 changed in 0.5 hours.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.148.1.6856832

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Thickman, D. I., Kundel, H. L., & Wolf, G.
Venue
Radiology
Published
1983-07
Volume
148
Issue
1
Pages
183-185
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2100073138
Cited by
103
References
0
FWCI
5.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nuclear magnetic resonance characteristics of fresh and fixed tissue: the effect of elapsed time. https://app.cochat.ai/papers/10.1148/radiology.148.1.6856832
The paper
Thickman, D. I., Kundel, H. L., & Wolf, G. (1983). Nuclear magnetic resonance characteristics of fresh and fixed tissue: the effect of elapsed time. Radiology. https://doi.org/10.1148/radiology.148.1.6856832

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.