Nuclear magnetic resonance characteristics of fresh and fixed tissue: the effect of elapsed time.
The DOI matches its Crossref record.
Abstract
The nuclear magnetic resonance relaxation times T1 and T2 of liver and spleen from freshly euthanized rats were measured over 48 hours for samples treated with normal saline, fixed with 70% ethanol, neutral buffered formalin, or 10% formalin, or left untreated. The initial values of T1 and T2 for both tissues agreed with previous determinations. For untreated tissues of both liver and spleen, T1 was stable for 6 hours and T2 was stable for 48 hours. For fixed tissues, T1 was stable for 0.5 hours, but T2 changed in 0.5 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The diagnostic accuracy of ex vivo MRI for human atherosclerotic plaque characterization
Shinnar, M., Fallon, J. T., Wehrli, S., Levin, M., Dalmacy, D., Fayad, Z. A., Badimon, J. J., Harrington, M., Harrington, E., & Fuster, V. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.11.2756 · Cited by 316
Investigation of Low Frequency Drift in fMRI Signal
Smith, A. M., Lewis, B. K., Ruttimann, U. E., Ye, F. Q., Sinnwell, T. M., Yang, Y., Duyn, J. H., & Frank, J. A. (1999) · NeuroImage · doi:10.1006/nimg.1999.0435 · Cited by 313
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305
Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times
Ramani, A., Dalton, C., Miller, D. H., Tofts, P. S., & Barker, G. J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00598-2 · Cited by 240
T 2 -Weighted Contrast for NMR Characterization of Human Atherosclerosis
Toussaint, J.-F., Southern, J. F., Fuster, V., & Kantor, H. L. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvb.15v10.1533 · Cited by 218
MR microscopy and high resolution small animal MRI: applications in neuroscience research
Benveniste, H., & Blackband, S. (2002) · Progress in Neurobiology · doi:10.1016/s0301-0082(02)00020-5 · Cited by 209
Postmortem MRI of human brain hemispheres: T 2 relaxation times during formaldehyde fixation
Dawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21909 · Cited by 162
Effects of formalin fixation and temperature on MR relaxation times in the human brain
Birkl, C., Langkammer, C., Golob‐Schwarzl, N., Leoni, M., Haybaeck, J., Goessler, W., Fazekas, F., & Ropele, S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3477 · Cited by 111
“induced dehydration (17), crosslinking (12,18) and reduced transmembrane water exchange (15,19).”
BackgroundDusek, P., Madai, V. I., Huelnhagen, T., Bahn, E., Matej, R., Sobesky, J., Niendorf, T., Acosta‐Cabronero, J., & Wuerfel, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27595 · Cited by 22
Metadata
- Authors
- Thickman, D. I., Kundel, H. L., & Wolf, G.
- Venue
- Radiology
- Published
- 1983-07
- Volume
- 148
- Issue
- 1
- Pages
- 183-185
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2100073138
- Cited by
- 103
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.