Dual-photon Gd-153 absorptiometry of bone.
The DOI matches its Crossref record.
Abstract
Dual-photon absorptiometry with gadolinium 153 was used to measure the mineral content of lumbar vertebrae in cadavers, excised vertebrae with marrow, and dry, marrow-free vertebrae. The error introduced by the surrounding soft tissue of cadavers was 3%, and the error in determining mineral mass or density in excised vertebrae was about 5%. The correlation coefficient between the results of Gd-153 and corrected iodine 125 (single-photon) absorptiometry on 24 femoral necks was 0.99, and the predictive error was 3.7%. Dual-photon absorptiometry accurately indicates bone mass and bone density and is only slightly affected by either surrounding tissue or fat changes in bone marrow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Riggs, B. L., & Melton, L. J. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606263142605 · Cited by 1,915
Bone Gain in Young Adult Women
Recker, R. R. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490170075028 · Cited by 845
Skeletal disease in primary hyperparathyroidism
Silverberg, S. J., Shane, E., de la Cruz, L., Dempster, D. W., Feldman, F., Seldin, D., Jacobs, T. P., Siris, E. S., Cafferty, M., Parisien, M. V., et al. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040302 · Cited by 625
Self-citationPerformance evaluation of a dual-energy X-ray bone densitometer
Mazess, R., Collick, B., Trempe, J., Barden, H., & Hanson, J. (1989) · Calcified Tissue International · doi:10.1007/bf02556569 · Cited by 352
Self-citationQuality of life issues in women with vertebral fractures due to osteoporosis
Cook, D. J., Guyatt, G. H., Adachi, J. D., Clifton, J., Griffith, L. E., Epstein, R. S., & Juneper, E. F. (1993) · Arthritis & Rheumatism · doi:10.1002/art.1780360603 · Cited by 323
Metadata
- Authors
- Wahner, H. W., Dunn, W. L., Mazess, R. B., Towsley, M., Lindsay, R., Markhard, L., & Dempster, D.
- Venue
- Radiology
- Published
- 1985-07
- Volume
- 156
- Issue
- 1
- Pages
- 203-206
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2076349990
- Cited by
- 124
- References
- 0
- FWCI
- 20.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-photon Gd-153 absorptiometry of bone. https://app.cochat.ai/papers/10.1148/radiology.156.1.4001406
- The paper
- Wahner, H. W., Dunn, W. L., Mazess, R. B., Towsley, M., Lindsay, R., Markhard, L., & Dempster, D. (1985). Dual-photon Gd-153 absorptiometry of bone. Radiology. https://doi.org/10.1148/radiology.156.1.4001406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.