Dual-photon Gd-153 absorptiometry of bone.

Wahner, H W, Dunn, W L, Mazess, R B, Towsley, M, Lindsay, R, Markhard, L, Dempster, D · 1985 · Radiology
Cited by 124

The DOI matches its Crossref record.

Abstract

Dual-photon absorptiometry with gadolinium 153 was used to measure the mineral content of lumbar vertebrae in cadavers, excised vertebrae with marrow, and dry, marrow-free vertebrae. The error introduced by the surrounding soft tissue of cadavers was 3%, and the error in determining mineral mass or density in excised vertebrae was about 5%. The correlation coefficient between the results of Gd-153 and corrected iodine 125 (single-photon) absorptiometry on 24 femoral necks was 0.99, and the predictive error was 3.7%. Dual-photon absorptiometry accurately indicates bone mass and bone density and is only slightly affected by either surrounding tissue or fat changes in bone marrow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.156.1.4001406

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Wahner, H. W., Dunn, W. L., Mazess, R. B., Towsley, M., Lindsay, R., Markhard, L., & Dempster, D.
Venue
Radiology
Published
1985-07
Volume
156
Issue
1
Pages
203-206
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2076349990
Cited by
124
References
0
FWCI
20.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-photon Gd-153 absorptiometry of bone. https://app.cochat.ai/papers/10.1148/radiology.156.1.4001406
The paper
Wahner, H. W., Dunn, W. L., Mazess, R. B., Towsley, M., Lindsay, R., Markhard, L., & Dempster, D. (1985). Dual-photon Gd-153 absorptiometry of bone. Radiology. https://doi.org/10.1148/radiology.156.1.4001406

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.