Gd-DOTA: characterization of a new paramagnetic complex.
The DOI matches its Crossref record.
Abstract
The relaxivity, biodistribution, and toxicity of the gadolinium-tetraazacyclododecanetetraacetic acid (Gd-DOTA) complex were evaluated. This cyclic complex has much greater in vitro stability (10(28)) than similar noncyclic complexes such as gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) (10(23)) or gadolinium-ethylenediaminetetraacetic acid (Gd-EDTA) (10(17)). The T1 relaxivity of Gd-DOTA (meglumine salt) determined in saline and in liver tissue at 20 MHz was similar to the relaxivity of Gd-DTPA. Tissue proton relaxation enhancement (PRE) correlated closely with chemical measurement of tissue gadolinium concentration. In rats, the biodistribution of Gd-DOTA was similar to Gd-DTPA with a distribution half-life of 3 minutes and an elimination half-life of 18 minutes. The median lethal dose (LD50) in mice of Gd-DOTA was 93% higher than that of Gd-DTPA; the calculated safety factor (ratio of LD50 to effective dose) was 53 for Gd-DOTA and 28 for Gd-DTPA. The data suggest that in vitro stability correlates with in vivo safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lanthanide induced shifts and relaxation rate enhancements
Peters, J. A., Huskens, J., & Raber, D. J. (1996) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(95)01026-2 · Cited by 508
Laurent, S., Elst, L. V., & Muller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.100 · Cited by 441
Idée, J., Port, M., Raynal, I., Schaefer, M., Le Greneur, S., & Corot, C. (2006) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2006.00447.x · Cited by 395
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
What nephrologists need to know about gadolinium
Penfield, J. G., & Reilly, R. F. (2007) · Nature Clinical Practice Nephrology · doi:10.1038/ncpneph0660 · Cited by 335
Banerjee, S., Pillai, M. R. A., & Knapp, F. F. (. (2015) · Chemical Reviews · doi:10.1021/cr500171e · Cited by 321
Ersoy, H., & Rybicki, F. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21135 · Cited by 283
Metal complexes as diagnostic tools
Reichert, D. E., Lewis, J. S., & Anderson, C. J. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00207-0 · Cited by 263
The Synthesis and Chelation Chemistry of DOTA−Peptide Conjugates
De León-Rodríguez, L. M., & Kovacs, Z. (2008) · Bioconjugate Chemistry · doi:10.1021/bc700328s · Cited by 262
Assessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Robert, P., Violas, X., Grand, S., Lehericy, S., Idée, J.-M., Ballet, S., & Corot, C. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000241 · Cited by 212
Measurement of gastric emptying by magnetic resonance imaging in humans
Schwizer, W., Maecke, H., & Michael, F. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)90823-h · Cited by 165
Lerat-Hardy, A., Coynel, A., Dutruch, L., Pereto, C., Bossy, C., Gil-Diaz, T., Capdeville, M.-J., Blanc, G., & Schäfer, J. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2018.11.343 · Cited by 113
Metadata
- Authors
- Bousquet, J. C., Saini, S., Stark, D. D., Hahn, P. F., Nigam, M., Wittenberg, J., & Ferrucci, J. T.
- Venue
- Radiology
- Published
- 1988-03
- Volume
- 166
- Issue
- 3
- Pages
- 693-698
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2090437724
- Cited by
- 257
- References
- 0
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.