The DOI matches its Crossref record.
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Abstract
Intravoxel incoherent motion (IVIM) imaging is a method the authors developed to visualize microscopic motions of water. In biologic tissues, these motions include molecular diffusion and microcirculation of blood in the capillary network. IVIM images are quantified by an apparent diffusion coefficient (ADC), which integrates the effects of both diffusion and perfusion. The aim of this work was to demonstrate how much perfusion contributes to the ADC and to present a method for obtaining separate images of diffusion and perfusion. Images were obtained at 0.5 T with high-resolution multisection sequences and without the use of contrast material. Results in a phantom made of resin microspheres demonstrated the ability of the method to separately evaluate diffusion and perfusion. The method was then applied in patients with brain and bone tumors and brain ischemia. Clinical results showed significant promise of the method for tissue characterization by perfusion patterns and for functional studies in the evaluation of the microcirculation in physiologic and pathologic conditions, as, for instance, in brain ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Self-citation
Metadata
- Authors
- Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M.
- Venue
- Radiology
- Published
- 1988-08
- Volume
- 168
- Issue
- 2
- Pages
- 497-505
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2139794744
- Cited by
- 3,169
- References
- 0
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. https://app.cochat.ai/papers/10.1148/radiology.168.2.3393671
- The paper
- Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988). Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology. https://doi.org/10.1148/radiology.168.2.3393671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.