The DOI matches its Crossref record.
Detection of focal hepatic masses: prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging.
Abstract
The sensitivities of contrast medium-enhanced computed tomography (CT), delayed CT (DCT), CT during arterial portography (CTAP), and magnetic resonance (MR) imaging for detecting focal liver lesions were prospectively evaluated in eight patients who subsequently underwent hepatic lobectomy or transplantation. Pathologic evaluation of the resected liver specimens demonstrated 37 lesions. The sensitivities were 81% (30 of 37 lesions) for CTAP, 57% (21 of 37 lesions) for MR imaging, 52% (12 of 23 lesions) for DCT, and 38% (14 of 37 lesions) for contrast-enhanced CT. The difference between the sensitivity of CTAP and the sensitivities of the other imaging tests was statistically significant (P less than .004). Of the lesions smaller than 1 cm in diameter, CTAP depicted 61% (11 of 18 lesions), MR imaging 17% (three of 18 lesions), CT 0% (zero of 18 lesions), and DCT 0% (zero of nine lesions). It is concluded that for preoperative detection of focal hepatic masses, CTAP is the most accurate technique available to most radiologists. Patients with primary or secondary hepatic neoplasms who are being considered for hepatic resection should undergo CTAP as part of their preoperative examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Omata, M., Lesmana, L. A., Tateishi, R., Chen, P.-J., Lin, S.-M., Yoshida, H., Kudo, M., Lee, J. M., Choi, B. I., Poon, R. T. P., et al. (2010) · Hepatology International · doi:10.1007/s12072-010-9165-7 · Cited by 1,026
Self-citationFor the European EOB-study group, Hammerstingl, R., Huppertz, A., Breuer, J., Balzer, T., Blakeborough, A., Carter, R., Fusté, L. C., Heinz-Peer, G., Judmaier, W., et al. (2008) · European Radiology · doi:10.1007/s00330-007-0716-9 · Cited by 384
An automatic diagnostic system for CT liver image classification
Chen, E.-L., Chung, P.-C., Chen, C.-L., Tsai, H.-M., & Chang, C.-I. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.678613 · Cited by 295
Understanding and optimizing use of contrast material for CT of the liver.
Baron, R. L. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.2.8037023 · Cited by 273
Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040508 · Cited by 187
Metadata
- Authors
- Heiken, J. P., Weyman, P. J., Lee, J. K., Balfe, D. M., Picus, D., Brunt, E. M., & Flye, M. W.
- Venue
- Radiology
- Published
- 1989-04
- Volume
- 171
- Issue
- 1
- Pages
- 47-51
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2005997839
- Cited by
- 315
- References
- 0
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of focal hepatic masses: prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging. https://app.cochat.ai/papers/10.1148/radiology.171.1.2538862
- The paper
- Heiken, J. P., Weyman, P. J., Lee, J. K., Balfe, D. M., Picus, D., Brunt, E. M., & Flye, M. W. (1989). Detection of focal hepatic masses: prospective evaluation with CT, delayed CT, CT during arterial portography, and MR imaging. Radiology. https://doi.org/10.1148/radiology.171.1.2538862
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.