Measuring signal-to-noise ratios in MR imaging.
The DOI matches its Crossref record.
Abstract
The signal-to-noise ratio (S/N) in magnetic resonance imagining is one of the variables that must be measured when comparing the relative performance of different techniques. Although various investigators and official groups have proposed different methods for measuring S/N, these are generally not practical for use by a physician working in a clinical situation. The authors present a simple method that should serve for estimating S/N in most cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession
Carr, J. C., Simonetti, O., Bundy, J., Li, D., Pereles, S., & Finn, J. P. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn44828 · Cited by 468
Quantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Maximum-likelihood estimation of Rician distribution parameters
Sijbers, J., den Dekker, A. J., Scheunders, P., & Van Dyck, D. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712125 · Cited by 393
Bogner, W., Gruber, S., Pinker, K., Grabner, G., Stadlbauer, A., Weber, M., Moser, E., Helbich, T. H., & Trattnig, S. (2009) · Radiology · doi:10.1148/radiol.2532081718 · Cited by 279
Estimation of the Noise in Magnitude MR Images
Sijbers, J., den Dekker, A. J., Van Audekerke, J., Verhoye, M., & Van Dyck, D. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00199-9 · Cited by 277
Review of medical image quality assessment
Chow, L. S., & Paramesran, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.02.006 · Cited by 265
Introduction to Microwave Imaging
Nikolova, N. K. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316084267 · Cited by 263
A comparison of two methods for measuring the signal to noise ratio on MR images
Firbank, M. J., Coulthard, A., Harrison, R. M., & Williams, E. D. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/12/403 · Cited by 256
Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., & Schoenberg, S. O. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.02.001 · Cited by 254
Direct Structural Connections between Voice- and Face-Recognition Areas
Blank, H., Anwander, A., & von Kriegstein, K. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2091-11.2011 · Cited by 165
“The constant scaling factor (0.655) corrects for the Rician distribution of the background noise (Kaufman et al., 1989; Firbank et al., 1999).”
BackgroundInfluential
Metadata
- Authors
- Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A.
- Venue
- Radiology
- Published
- 1989-10
- Volume
- 173
- Issue
- 1
- Pages
- 265-267
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2035246484
- Cited by
- 360
- References
- 0
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.