Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Diffusion-weighted MR for Differentiation of Breast Lesions at 3.0 T: How Does Selection of Diffusion Protocols Affect Diagnosis?

Bogner, Wolfgang, Gruber, Stephan, Pinker, Katja, Grabner, Günther, Stadlbauer, Andreas, Weber, Michael, Moser, Ewald, Helbich, Thomas H., Trattnig, Siegfried · 2009 · Radiology

Abstract

PURPOSE: To compare the diagnostic quality of diffusion-weighted (DW) imaging schemes with regard to apparent diffusion coefficient (ADC) accuracy, ADC precision, and DW imaging contrast-to-noise ratio (CNR) for different types of lesions and breast tissue. MATERIALS AND METHODS: Institutional review board approval and written, informed consent were obtained. Fifty-one patients with histopathologic correlation or follow-up performed with a 3.0-T MR imager were included in this study. There were 112 regions of interest drawn in 24 malignant, 17 benign, 20 cystic, and 51 normal tissue regions. ADC maps were calculated for combinations of 10 b values (range, 0-1250 sec/mm(2)). Differences in ADC among tissue types were evaluated. The CNRs of lesions at DW imaging were compared for all b values. A repeated-measures analysis of variance was used to assess lesion differentiation. RESULTS: ADCs calculated from b values of 50 and 850 sec/mm(2) were 0.99 x 10(-3) mm(2)/sec +/- 0.18 (standard deviation), 1.47 x 10(-3) mm(2)/sec +/- 0.21, 1.85 x 10(-3) mm(2)/sec +/- 0.22, and 2.64 x 10(-3) mm(2)/sec +/- 0.30 for malignant, benign, normal, and cystic tissues, respectively. An ADC threshold level of 1.25 x 10(-3) mm(2)/sec allowed discrimination between malignant and benign lesions with a diagnostic accuracy of 95% (P < .001). ADC calculations performed with multiple b values were not significantly more precise than those performed with only two. We found an overestimation of ADC for maximum b values of up to 1000 sec/mm(2). The best CNR for tumors was identified at 850 sec/mm(2). CONCLUSION: Optimum ADC determination and DW imaging quality at 3.0 T was found with a combined b value protocol of 50 and 850 sec/mm(2). This provided a high accuracy for differentiation of benign and malignant breast tumors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2532081718

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 279

Metadata

Authors
Bogner, W., Gruber, S., Pinker, K., Grabner, G., Stadlbauer, A., Weber, M., Moser, E., Helbich, T. H., & Trattnig, S.
Venue
Radiology
Published
2009-11
Volume
253
Issue
2
Pages
341-351
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2149130813
Cited by
279
References
20
FWCI
12.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diffusion-weighted MR for Differentiation of Breast Lesions at 3.0 T: How Does Selection of Diffusion Protocols Affect Diagnosis? https://app.cochat.ai/papers/10.1148/radiol.2532081718
The paper
Bogner, W., Gruber, S., Pinker, K., Grabner, G., Stadlbauer, A., Weber, M., Moser, E., Helbich, T. H., & Trattnig, S. (2009). Diffusion-weighted MR for Differentiation of Breast Lesions at 3.0 T: How Does Selection of Diffusion Protocols Affect Diagnosis? Radiology. https://doi.org/10.1148/radiol.2532081718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.