The DOI matches its Crossref record.
Cerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T.
Abstract
The authors assessed regional cerebral blood flow dynamics with magnetic resonance (MR) imaging enhanced with gadolinium diethylenetriaminepentaacetic acid (DTPA). After bolus administration of Gd-DTPA, rapid T2*-weighted gradient-echo images were acquired. Image acquisition time ranged from 2 to 3 seconds. The signal intensity (SI) of brain tissue and blood vessels markedly decreased during the first pass of contrast agent through the brain due to the local field inhomogeneity caused by the concentrated paramagnetic contrast agent. The method was used in 18 subjects with no cerebrovascular disease and 32 patients with stroke, vascular stenosis, arteriovenous malformation, and cerebral neoplasm. Comparison with intracranial angiography was performed in three patients and with single-photon emission computed tomography of blood flow in four. The change in T2* relaxation rate was approximately linearly related to the dose of contrast agent. The SI change increased as the echo time was lengthened. Regions in cerebral infarcts, metastases, and arteriovenous malformations showed different enhancement patterns than those of edema around a lesion and of normal brain tissue. Abnormal circulation times in patients with vascular stenoses were demonstrated. The method provides information about cerebral blood flow dynamics not available from conventional MR imaging and MR angiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Edelman, R. R., & Warach, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303183281109 · Cited by 1,206
Self-citationWarach, S., Dashe, J. F., & Edelman, R. R. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199601000-00006 · Cited by 490
Self-citationEllingson, B. M. (2015) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-014-0506-0 · Cited by 132
Luckhaus, C., Flüß, M. O., Wittsack, H.-J., Grass-Kapanke, B., Jänner, M., Khalili-Amiri, R., Friedrich, W., Supprian, T., Gaebel, W., Mödder, U., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.053 · Cited by 88
Vascular microenvironment in gliomas
Vajkoczy, P., & Menger, M. D. (2004) · Cancer Treatment and Research · doi:10.1007/978-1-4419-8871-3_15 · Cited by 62
Metadata
- Authors
- Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J.
- Venue
- Radiology
- Published
- 1990-07
- Volume
- 176
- Issue
- 1
- Pages
- 211-220
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2129439238
- Cited by
- 304
- References
- 0
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T. https://app.cochat.ai/papers/10.1148/radiology.176.1.2353094
- The paper
- Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J. (1990). Cerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T. Radiology. https://doi.org/10.1148/radiology.176.1.2353094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.