The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Magnetic Resonance Imaging
Abstract
Musculoskeletal SystemMRI is widely used to assist in the diagnosis of joint injuries, bone marrow disorders, soft-tissue tumors, and other musculoskeletal abnormalities. Fibrocartilage and ligaments normally appear dark because of a paucity of mobile protons61. In the knee, MRI has a reported sensitivity of 75 to 100 percent for the identification of meniscal tears, as indicated by an increased signal intensity in the fibrocartilaginous meniscus that extends to an articular surface (Figure 6A). MRI has largely supplanted arthrography62,63. Meniscal degeneration not seen at arthroscopy is detected as an increase in intrameniscal signal intensity; this finding is . . .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
The Diagnosis of Thoracic Aortic Dissection by Noninvasive Imaging Procedures
Nienaber, C. A., von Kodolitsch, Y., Nicolas, V., Siglow, V., Piepho, A., Brockhoff, C., Koschyk, D. H., & Spielmann, R. P. (1993) · New England Journal of Medicine · doi:10.1056/nejm199301073280101 · Cited by 970
Fast magnetic resonance diffusion-weighted imaging of acute human stroke
Warach, S., Chien, D., Li, W., Ronthal, M., & Edelman, R. R. (1992) · Neurology · doi:10.1212/wnl.42.9.1717 · Cited by 881
Self-citationEcho-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Cerebral angiographic risk in mild cerebrovascular disease.
Hankey, G. J., Warlow, C. P., & Sellar, R. J. (1990) · Stroke · doi:10.1161/01.str.21.2.209 · Cited by 503
Comparison of Magnetic Resonance Imaging and Ultrasonography in Staging Early Prostate Cancer
Rifkin, M. D., Zerhouni, E. A., Gatsonis, C. A., Quint, L. E., Paushter, D. M., Epstein, J. I., Hamper, U. M., Walsh, P. C., & McNeil, B. J. (1990) · New England Journal of Medicine · doi:10.1056/nejm199009063231001 · Cited by 500
Owen, R. S., Carpenter, J. P., Baum, R. A., Perloff, L. J., & Cope, C. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206113262428 · Cited by 307
Cited by
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Amyloid imaging results from the Australian Imaging, Biomarkers and Lifestyle (AIBL) study of aging
Rowe, C. C., Ellis, K. A., Rimajova, M., Bourgeat, P., Pike, K. E., Jones, G., Fripp, J., Tochon-Danguy, H., Morandeau, L., O'Keefe, G., et al. (2010) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.04.007 · Cited by 986
Gallay, B. J., Ahmad, S., Xu, L., Toivola, B., & Davidson, R. C. (2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)80117-7 · Cited by 304
Metadata
- Authors
- Edelman, R. R., & Warach, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1993-03-18
- Volume
- 328
- Issue
- 11
- Pages
- 785-791
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2403112195
- Cited by
- 1,206
- References
- 25
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1056/nejm199303183281109
- The paper
- Edelman, R. R., & Warach, S. (1993). Magnetic Resonance Imaging. New England Journal of Medicine. https://doi.org/10.1056/nejm199303183281109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.