CoChat

Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging.

Senéterre, E, Weissleder, R, Jaramillo, D, Reimer, P, Lee, A S, Brady, T J, Wittenberg, J · 1991 · Radiology
Cited by 109

The DOI matches its Crossref record.

Abstract

An ultrasmall superparamagnetic iron oxide (USPIO) preparation was evaluated as a potential intravenous contrast agent for magnetic resonance (MR) imaging of bone marrow. One hour after administration of USPIO (40, 80, and 160 mumols of iron per kilogram body weight) in rats and rabbits, T1 and T2 relaxation times were, respectively, approximately 30%, 50%, and 65% lower than precontrast relaxation times. Maximum decrease in relaxation times of marrow occurred within 1-24 hours after intravenous administration; thereafter, relaxation times slowly returned to normal within 7 days. In vivo MR imaging of rabbits and rats confirmed that USPIO decreases signal intensity of red and yellow marrow. The decrease was most marked with gradient echo pulse sequences. An animal model of intramedullary tumor demonstrated the potential of USPIO to enable differentiation between tumor and normal red marrow. USPIO-enhanced MR imaging improves detection of smaller tumors and allows differentiation of tumor deposits from islands of hyperplastic or normal red marrow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.179.2.2014305

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Senéterre, E., Weissleder, R., Jaramillo, D., Reimer, P., Lee, A. S., Brady, T. J., & Wittenberg, J.
Venue
Radiology
Published
1991-05
Volume
179
Issue
2
Pages
529-533
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2091626219
Cited by
109
References
0
FWCI
2.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging. https://app.cochat.ai/papers/10.1148/radiology.179.2.2014305
The paper
Senéterre, E., Weissleder, R., Jaramillo, D., Reimer, P., Lee, A. S., Brady, T. J., & Wittenberg, J. (1991). Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging. Radiology. https://doi.org/10.1148/radiology.179.2.2014305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.