GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.
The DOI matches its Crossref record.
Abstract
A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical whole-body MR systems without modification of gradient hardware. Image acquisition time is 18 seconds for 11 multisection body images (2,000/80 [repetition time msec/echo time msec]) and 36 seconds for 22 brain images (4,000/104). With a combination of multiple Hahn spin echoes and short gradient-echo trains, the GRASE technique overcomes several potential problems of echo-planar imaging, including large chemical shift, image distortions, and signal loss from field inhomogeneity. Advantages of GRASE over the RARE (rapid acquisition with relaxation enhancement) technique include faster acquisition times and lower deposition of radio-frequency power in the body. Breath holding during 18-second GRASE imaging of the upper abdomen eliminates respiratory-motion artifacts in T2-weighted images. A major improvement in T2-weighted abdominal imaging is suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Self-citationOptimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence
Prasloski, T., Rauscher, A., MacKay, A. L., Hodgson, M., Vavasour, I. M., Laule, C., & Mädler, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.064 · Cited by 268
Barbosa, J. H. O., Santos, A. C., Tumas, V., Liu, M., Zheng, W., Haacke, E. M., & Salmon, C. E. G. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.02.021 · Cited by 258
Peled, S., & Yeshurun, Y. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<29::aid-mrm1005>3.0.co;2-z · Cited by 235
“Other single-shot techniques, such as those based on RARE (6), and GRASE (7) acquisition schemes, could possibly also be modified to provide diffusion weighting.”
MethodFunctional magnetic resonance imaging of the human brain: data acquisition and analysis
Turner, R., Howseman, A., Rees, G. E., Josephs, O., & Friston, K. (1998) · Experimental Brain Research · doi:10.1007/s002210050538 · Cited by 200
“Furthermore, the rate of information capture, that is, the signal-to-noise per unit time, is highest for EPI and its variants [such as single-shot GRASE (Feinberg and Oshio 1991) and single-shot spiral EPI (Ahn et al. 1986)].”
BackgroundAn interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
Uddin, M. N., Figley, T. D., Marrie, R. A., Figley, C. R., & for the CCOMS Study Group (2018) · NMR in Biomedicine · doi:10.1002/nbm.3868 · Cited by 84
Metadata
- Authors
- Feinberg, D. A., & Oshio, K.
- Venue
- Radiology
- Published
- 1991-11
- Volume
- 181
- Issue
- 2
- Pages
- 597-602
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2104266850
- Cited by
- 197
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.