Missed bronchogenic carcinoma: radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect.
The DOI matches its Crossref record.
Abstract
Eighteen radiologists failed to detect 27 potentially resectable bronchogenic carcinomas revealed retrospectively on serial chest radiographs. Most of the cancers were in an upper lobe (n = 22 [81%]), especially the right upper lobe (n = 15 [56%]). More of the cancers were in women (n = 18 [67%]) than in men (n = 9 [33%]). The mean diameter of the missed lesions was 1.6 cm +/- 0.8 (range, 0.6-3.4 cm). Only two lesions (7%) were well defined around their entire extent. A lateral radiograph (available for 23 patients) revealed the missed lesion better than the posteroanterior radiograph in four patients (17%). Six consultant radiologists, who were biased by knowledge that the cases were of missed bronchogenic carcinoma, were individually shown the radiographs in 22 of the cases. Each consultant missed a mean of 26% (5.8 +/- 1.7) of the lesions. At least one of the six consultants missed the lesion in 16 (73%) of the cases. The predominant characteristics of radiographically missed and potentially resectable bronchogenic carcinomas were difficulty in radiographic detection, female gender, and location in an upper lobe, especially on the right side.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[106] Austin JH, Romney BM, Goldsmith LS.”
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Nam, J. G., Park, S., Hwang, E. J., Lee, J. H., Jin, K.-N., Lim, K. Y., Vu, T. H., Sohn, J. H., Hwang, S., Goo, J. M., et al. (2019) · Radiology · doi:10.1148/radiol.2018180237 · Cited by 539
High‐Resolution Computed Tomography for the Diagnosis of Community‐Acquired Pneumonia
Syrjala, H., Broas, M., Suramo, I., Ojala, A., & Lahde, S. (1998) · Clinical Infectious Diseases · doi:10.1086/514675 · Cited by 343
Miss Rate of Lung Cancer on the Chest Radiograph in Clinical Practice
Quekel, L. G. B. A., Kessels, A. G. H., Goei, R., & van Engelshoven, J. M. A. (1999) · Chest · doi:10.1378/chest.115.3.720 · Cited by 311
Fool Me Twice: Delayed Diagnoses in Radiology With Emphasis on Perpetuated Errors
Kim, Y. W., & Mansfield, L. T. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11493 · Cited by 259
Sim, Y., Chung, M. J., Kotter, E., Yune, S., Kim, M., Do, S., Han, K., Kim, H., Yang, S., Lee, D.-J., et al. (2020) · Radiology · doi:10.1148/radiol.2019182465 · Cited by 248
Suzuki, K., Abe, H., MacMahon, H., & Doi, K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871549 · Cited by 237
“radiographs, however, can be overlooked by radiologists in from 12%–90% of cases in which nodules are visible in retrospect [10], [11].”
BackgroundSpectrum of diagnostic errors in radiology
Pinto, A. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.377 · Cited by 202
Shah, P. K., Austin, J. H. M., White, C. S., Patel, P., Haramati, L. B., Pearson, G. D. N., Shiau, M. C., & Berkmen, Y. M. (2003) · Radiology · doi:10.1148/radiol.2261011924 · Cited by 198
“cases in the study of Austin et al [17]) or”
BackgroundSelf-citationPrävention, Diagnostik, Therapie und Nachsorge des Lungenkarzinoms
Goeckenjan, G., Sitter, H., Thomas, M., Branscheid, D., Flentje, M., Griesinger, F., Niederle, N., Stuschke, M., Blum, T., Deppermann, K.-M., et al. (2010) · Pneumologie · doi:10.1055/s-0029-1243837 · Cited by 165
Accuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Berlin, L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1270 · Cited by 165
“Additional studies conducted by researchers at major academic medical centers disclosed that from 26% to 90% of all lung carcinomas were missed by radiologists interpreting chest radiographs [31–33].”
BackgroundAhn, J. S., Ebrahimian, S., McDermott, S., Lee, S., Naccarato, L., Di Capua, J. F., Wu, M. Y., Zhang, E. W., Muse, V., Miller, B., et al. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.29289 · Cited by 138
Errors in cancer diagnosis: current understanding and future directions
Singh, H., Sethi, S., Raber, M., & Petersen, L. A. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.2142 · Cited by 121
Improving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Pitfalls in Chest Radiographic Interpretation: Blind Spots
de Groot, P. M., Carter, B. W., Abbott, G. F., & Wu, C. C. (2015) · Seminars in Roentgenology · doi:10.1053/j.ro.2015.01.008 · Cited by 44
Lee, K. H., Goo, J. M., Park, C. M., Lee, H. J., & Jin, K. N. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.5.564 · Cited by 37
“However, it is not without its problems; malignant lung nodules are frequently overlooked and missed on chest radiograph, even by experienced radiologists (1-4), and many of them detected retrospectively (2-4).”
BackgroundWhere Are They All Hiding? Common Blind Spots on Chest Radiography
Humphrey, K. L., Wu, C. C., Gilman, M. D., El-Sherief, A. H., Shepard, J.-A. O., & Abbott, G. F. (2011) · Contemporary Diagnostic Radiology · doi:10.1097/01.cdr.0000406727.37058.bc · Cited by 5
Metadata
- Authors
- Austin, J. H., Romney, B. M., & Goldsmith, L. S.
- Venue
- Radiology
- Published
- 1992-01
- Volume
- 182
- Issue
- 1
- Pages
- 115-122
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2096734290
- Cited by
- 266
- References
- 0
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.